ICRU Report 98, Stochastic Nature of Radiation Interactions: Microdosimetry

LA Braby, V Conte, M Dingfelder… - Journal of the …, 2023 - journals.sagepub.com
ICRU Report 98, Stochastic Nature of Radiation Interactions: Microdosimetry - LA Braby, V.
Conte, M. Dingfelder, DT Goodhead, LS Pinsky, AB Rosenfeld, T. Sato, AJ Waker, S. Guatelli …

New technologies for beam spectrometry, quality assurance, real-time monitoring and microdosimetry in BNCT

H Kumada, A Masuda, H Tanaka, M Takada… - Radiation …, 2024 - Elsevier
Boron neutron capture therapy (BNCT) is a next-generation radiotherapy that combines
neutron beams with boron compounds that selectively accumulate in cancer cells. Because …

Microdosimetric analysis for boron neutron capture therapy via Monte Carlo track structure simulation with modified lithium cross-sections

Y Han, C Geng, JN D-Kondo, M Li… - Radiation Physics and …, 2023 - Elsevier
Boron neutron capture therapy (BNCT) is a cellular-level hadron therapy achieving
therapeutic effects via the synergistic action of multiple particles, including Lithium, alpha …

Microdosimetry of an accelerator based thermal neutron field for Boron Neutron Capture Therapy

A Selva, L Bellan, A Bianchi, G Giustiniani… - Applied Radiation and …, 2022 - Elsevier
Abstract The MUNES project (MUltidisciplinary NEutron Source) aims at the realization of an
intense accelerator-based source of thermal neutrons, suitable for Boron Neutron Capture …

Study of the relative dose-response of BANG-3® polymer gel dosimeters in epithermal neutron irradiation

J Uusi-Simola, S Savolainen… - Physics in Medicine …, 2003 - iopscience.iop.org
Polymer gels have been reported as a new, potential tool for dosimetry in mixed neutron–
gamma radiation fields. In this work, BANG-3 (MGS Research Inc.) gel vials from three …

Linear energy transfer and relative biological effectiveness

MC Joiner, JW Burmeister, W Dörr - Basic clinical radiobiology, 2018 - taylorfrancis.com
Modern radiotherapy is usually delivered using linear accelerators producing X-rays with
energies of 4–25 MV which have generally superseded therapy with lower energy 60Co or …

Effect of MLC leaf width on the planning and delivery of SMLC IMRT using the CORVUS inverse treatment planning system: Effect of MLC leaf width on IMRT plans

J Burmeister, PN McDermott, T Bossenberger… - Medical …, 2004 - Wiley Online Library
This study investigates the influence of multileaf collimator (MLC) leaf width on intensity
modulated radiation therapy (IMRT) plans delivered via the segmented multileaf collimator …

Simulation and first test of a microdosimetric detector based on a thick gas electron multiplier

SH Byun, GM Spirou, A Hanu… - … on Nuclear Science, 2009 - ieeexplore.ieee.org
We present design of a new microdosimetry detector based on thick gas electron multiplier
(THGEM). A prototype detector was designed for a cylindrical sensitive volume with 5 mm …

Boron neutron capture therapy: Microdosimetry at different boron concentrations

V Conte, A Bianchi, A Selva - Applied Sciences, 2023 - mdpi.com
Featured Application Application of microdosimetric techniques to characterize the mixed
radiation field in boron neutron capture therapy. Abstract This paper explores the role of …

[HTML][HTML] Microdosimetry for BNCT: First measurements at different site sizes

A Selva, A Bianchi, L Bellan, E Fagotti, A Pisent… - Radiation …, 2024 - Elsevier
Microdosimetric techniques are a valuable tool for beam quality monitoring in BNCT, due to
their capability to distinguish different contributions to the total dose and provide physics …