Artefacts in CBCT: a review

R Schulze, U Heil, D Groβ… - Dentomaxillofacial …, 2011 - academic.oup.com
Artefacts are common in today's cone beam CT (CBCT). They are induced by discrepancies
between the mathematical modelling and the actual physical imaging process. Since …

Metal artifact reduction in CT: where are we after four decades?

L Gjesteby, B De Man, Y Jin, H Paganetti… - Ieee …, 2016 - ieeexplore.ieee.org
Methods to overcome metal artifacts in computed tomography (CT) images have been
researched and developed for nearly 40 years. When X-rays pass through a metal object …

CT super-resolution GAN constrained by the identical, residual, and cycle learning ensemble (GAN-CIRCLE)

C You, G Li, Y Zhang, X Zhang, H Shan… - IEEE transactions on …, 2019 - ieeexplore.ieee.org
In this paper, we present a semi-supervised deep learning approach to accurately recover
high-resolution (HR) CT images from low-resolution (LR) counterparts. Specifically, with the …

Convolutional neural network based metal artifact reduction in X-ray computed tomography

Y Zhang, H Yu - IEEE transactions on medical imaging, 2018 - ieeexplore.ieee.org
In the presence of metal implants, metal artifacts are introduced to x-ray computed
tomography CT images. Although a large number of metal artifact reduction (MAR) methods …

Deep sinogram completion with image prior for metal artifact reduction in CT images

L Yu, Z Zhang, X Li, L Xing - IEEE transactions on medical …, 2020 - ieeexplore.ieee.org
Computed tomography (CT) has been widely used for medical diagnosis, assessment, and
therapy planning and guidance. In reality, CT images may be affected adversely in the …

Normalized metal artifact reduction (NMAR) in computed tomography

E Meyer, R Raupach, M Lell, B Schmidt… - Medical …, 2010 - Wiley Online Library
Purpose: While modern clinical CT scanners under normal circumstances produce high
quality images, severe artifacts degrade the image quality and the diagnostic value if metal …

[HTML][HTML] Radiation dose reduction in computed tomography: techniques and future perspective

L Yu, X Liu, S Leng, JM Kofler… - Imaging in …, 2009 - ncbi.nlm.nih.gov
Despite universal consensus that computed tomography (CT) overwhelmingly benefits
patients when used for appropriate indications, concerns have been raised regarding the …

On cone‐beam computed tomography artifacts induced by titanium implants

RKW Schulze, D Berndt… - Clinical oral implants …, 2010 - Wiley Online Library
Objectives: To briefly review the mathematical background of beam‐hardening artifacts in
cone‐beam computed tomography (CBCT)‐reconstruction and to investigate geometrical …

A review of the methods on cobb angle measurements for spinal curvature

C Jin, S Wang, G Yang, E Li, Z Liang - Sensors, 2022 - mdpi.com
Scoliosis is a common disease of the spine and requires regular monitoring due to its
progressive properties. A preferred indicator to assess scoliosis is by the Cobb angle, which …

Metal streak artifacts in X-ray computed tomography: a simulation study

B De Man, J Nuyts, P Dupont… - 1998 IEEE Nuclear …, 1998 - ieeexplore.ieee.org
Metal streak artifacts are an important problem in X-ray computed tomography. A high-
resolution 2D fan-beam computed tomography simulator is presented. Several potential …