Transformerless inverter topologies for single-phase photovoltaic systems: A comparative review

MNH Khan, M Forouzesh, YP Siwakoti… - IEEE Journal of …, 2019 - ieeexplore.ieee.org
In photovoltaic (PV) applications, a transformer is often used to provide galvanic isolation
and voltage ratio transformations between input and output. However, these conventional …

Overview of recent advanced topologies for transformerless dual-grounded inverters

X Guo, H Zhang, W Tang, Z Lu, C Hua… - … on Power Electronics, 2022 - ieeexplore.ieee.org
Transformerless inverters, most of which are H-bridge inverters, have been widely used and
studied in grid-connected power systems in the last decades. However, the H-bridge inverter …

A common ground five-level inverter using switched capacitor

K Ito, K Takahashi, H Koizumi - IECON 2019-45th Annual …, 2019 - ieeexplore.ieee.org
This paper proposes a common ground five-level inverter using switched capacitor. The
main features of the proposed inverter are the common ground structure, multilevel output …

Novel step-up transformerless inverter topology for 1-φ grid-connected photovoltaic system

PK Chamarthi, MS El Moursi… - IEEE Transactions …, 2021 - ieeexplore.ieee.org
In this article, a novel step-up transformerless inverter topology is presented for the grid-
connected solar PV system. The proposed topology has the features of a dc-dc step-up …

Data description technique-based islanding classification for single-phase grid-connected photovoltaic system

A Haque, A Alshareef, AI Khan, MM Alam… - Sensors, 2020 - mdpi.com
This paper develops an islanding classification mechanism to overcome the problems of
non-detection zones in conventional islanding detection mechanisms. This process is …

Common-ground transformerless inverter for solar photovoltaic module

SU Hasan, B Shaffer, HA Hassan… - 2018 IEEE Applied …, 2018 - ieeexplore.ieee.org
This paper presents a new single-phase transformerless inverter providing common ground
for grid-connected photovoltaic (PV) systems. It consists of 5 switches, one diode, one …

Photovoltaic inverter profiles in relation to the European network code NC RFG and the requirements of polish distribution system operators

K Chmielowiec, Ł Topolski, A Piszczek, Z Hanzelka - Energies, 2021 - mdpi.com
The presently observed rapid increase in photovoltaic (PV) micro-installation connections to
low-voltage networks, resulting from numerous financial support programmes, European …

Photovoltaic inverter reliability study through SiC switches redundant structures

I Villanueva, N Vázquez, J Vaquero, C Hernández… - Technologies, 2023 - mdpi.com
Reliability is a very important issue in power electronics; however, sometimes it is not
considered, studied, or analyzed. At present, renewables have become more popular, and …

Current source AC-Side clamped inverter for leakage current reduction in grid-connected PV system

X Li, N Wang, G San, X Guo - Electronics, 2019 - mdpi.com
For the grid-connected photovoltaic inverters, the switching-frequency common-mode
voltage brings the leakage current, which should be eliminated. So far, many kinds of single …

A novel three-switch Z-source SEPIC inverter

B Wang, W Tang - Electronics, 2019 - mdpi.com
In this paper, a novel single-phase transformerless Z-source inverter (ZSI) derived from the
basic SEPIC topology, which is named SEPIC-based ZSI, is proposed. The negative end of …