Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo‐based photon and electron external beam treatment planning

IJ Chetty, B Curran, JE Cygler, JJ DeMarco… - Medical …, 2007 - Wiley Online Library
The Monte Carlo (MC) method has been shown through many research studies to calculate
accurate dose distributions for clinical radiotherapy, particularly in heterogeneous patient …

Fifty years of Monte Carlo simulations for medical physics

DWO Rogers - Physics in Medicine & Biology, 2006 - iopscience.iop.org
Monte Carlo techniques have become ubiquitous in medical physics over the last 50 years
with a doubling of papers on the subject every 5 years between the first PMB paper in 1967 …

Dosimetric effects caused by couch tops and immobilization devices: report of AAPM Task Group 176

AJ Olch, L Gerig, H Li, I Mihaylov, A Morgan - Medical physics, 2014 - Wiley Online Library
The dosimetric impact from devices external to the patient is a complex combination of
increased skin dose, reduced tumor dose, and altered dose distribution. Although small …

Efficiency improvements for ion chamber calculations in high energy photon beams

J Wulff, K Zink, I Kawrakow - Medical physics, 2008 - Wiley Online Library
This article presents the implementation of several variance reduction techniques that
dramatically improve the simulation efficiency of ion chamber dose and perturbation factor …

Accurate skin dose measurements using radiochromic film in clinical applications

S Devic, J Seuntjens, W Abdel‐Rahman… - Medical …, 2006 - Wiley Online Library
Megavoltage x‐ray beams exhibit the well‐known phenomena of dose buildup within the
first few millimeters of the incident phantom surface, or the skin. Results of the surface dose …

AAA and PBC calculation accuracy in the surface build-up region in tangential beam treatments. Phantom and breast case study with the Monte Carlo code …

V Panettieri, P Barsoum, M Westermark… - Radiotherapy and …, 2009 - Elsevier
BACKGROUND AND PURPOSE: In tangential beam treatments accurate dose calculation of
the absorbed dose in the build-up region is of major importance, in particular when the …

Monte Carlo study of photon fields from a flattening filter‐free clinical accelerator

ON Vassiliev, U Titt, SF Kry, F Pönisch… - Medical …, 2006 - Wiley Online Library
In conventional clinical linear accelerators, the flattening filter scatters and absorbs a large
fraction of primary photons. Increasing the beam‐on time, which also increases the out‐of …

On the effective point of measurement in megavoltage photon beams

I Kawrakow - Medical physics, 2006 - Wiley Online Library
This paper presents a numerical investigation of the effective point of measurement of
thimble ionization chambers in megavoltage photon beams using Monte Carlo simulations …

An investigation of the depth dose in the build-up region, and surface dose for a 6-MV therapeutic photon beam: Monte Carlo simulation and measurements

L Apipunyasopon, S Srisatit… - Journal of radiation …, 2013 - academic.oup.com
The percentage depth dose in the build-up region and the surface dose for the 6-MV photon
beam from a Varian Clinac 23EX medical linear accelerator was investigated for square field …

The effective point of measurement of ionization chambers and the build‐up anomaly in MV x‐ray beams

MR McEwen, I Kawrakow, CK Ross - Medical physics, 2008 - Wiley Online Library
A precision experimental investigation of the effective point of measurement (EPOM) of ion
chambers in megavoltage beams has been carried out. A one‐dimensional scanning …