Phase-tilt iteration: Accurate and robust phase extraction from random tilt-shift interferograms

M Duan, Y Zong, R Zhu, J Li - Optics and Lasers in Engineering, 2021 - Elsevier
An advanced phase-tilt iteration method is proposed for accurate and robust phase
extraction from the interferograms with random tilt shift. The method constructs a system of …

Simultaneous extraction of phase and phase shift from two interferograms using Lissajous figure and ellipse fitting technology with Hilbert–Huang prefiltering

F Liu, J Wang, Y Wu, F Wu, M Trusiak… - Journal of …, 2016 - iopscience.iop.org
This paper presents a novel method to extract the phase shift and phase distribution from
two interferograms simultaneously. By employing Hilbert–Huang transform based …

Optical metrology for very large convex aspheres

JH Burge, P Su, C Zhao - Advanced Optical and Mechanical …, 2008 - spiedigitallibrary.org
Telescopes with very large diameter or with wide fields require convex secondary mirrors
that may be many meters in diameter. The optical surfaces for these mirrors can be …

Dynamic measurements using a Fizeau interferometer

DM Sykora, ML Holmes - Optical Measurement Systems for …, 2011 - spiedigitallibrary.org
Single-camera frame instantaneous interferometry is an alternative optical test method
where environmental noise prohibits conventional phase shifting methods. For the most …

Dynamic low-coherence interferometry using a double Fizeau cavity

Y Zong, M Duan, R Zhu, L Chen, J Li - Optics letters, 2021 - opg.optica.org
The coexistence of anti-vibration and a common optical path is difficult to realize in dynamic
Fizeau interferometry. To address this problem, we propose a dynamic low-coherence …

600-mm aperture simultaneous phase-shifting Fizeau interferometer

W Zhu, L Chen, Y Yang, R Zhang, D Zheng… - Optics & Laser …, 2018 - Elsevier
In this study, a 600-mm aperture simultaneous phase-shifting Fizeau interferometer is
presented. This interferometer has a special light source configuration produced by an …

Modelling and correction for polarization errors of a 600 mm aperture dynamic Fizeau interferometer

X Miao, J Ma, Y Yu, J Li, C Wei, R Zhu, L Chen… - Optics …, 2020 - opg.optica.org
The polarization errors of large aperture dynamic interferometers based on the polarization
phase shifting method are mainly coming from the effects of imperfect polarized elements …

System design and error correction for 300 mm aperture vertical Fizeau spatial-temporal phase-shifting interferometer

D Zheng, L Chen, L Kong, C Wang, C Hu, Y Wang… - Applied Optics, 2020 - opg.optica.org
With the development of high-power lasers for aerospace, electronics, etc., the demand for
large-aperture planar optical elements has become more urgent, along with the demand for …

Vibration-resistant Fizeau interferometry using three-cavity multiplexing

Y Zong, M Duan, C Yu, Y Liu, Y Zhong, H Huang, J Li - Optics Letters, 2024 - opg.optica.org
This study demonstrates a three-cavity multiplexing vibration-resistant Fizeau interferometry
(TCM). The method injects a vibration-measurement pass (VMP), which utilizes three-cavity …

Dual-mode Fizeau interferometer with four-step phase-tilting iteration for dynamic optical measurement

C Yu, Y Zong, M Duan, J Li - Optics Express, 2021 - opg.optica.org
For a conventional Fizeau interferometer, accommodating both anti-vibration and
conventional measurement modes is a challenge. Here, a dual-mode Fizeau interferometer …