A DFT-based phasor estimation method robust to primary and secondary decaying DC components

S Afrandideh, F Haghjoo - Electric Power Systems Research, 2022 - Elsevier
Fault current signals typically suffer from primary and secondary decaying DC (DDC)
components due to the transient response of the power system and current transformer. On …

An enhanced sub-cycle statistical algorithm for inrush and fault currents classification in differential protection schemes

M Tajdinian, M Allahbakhshi, A Bagheri… - International Journal of …, 2020 - Elsevier
Differential protection is a widely-used approach for power transformer protection, the
performance of which may be, at times, challenged due to the inrush current and current …

Application of probabilistic distance measures for inrush and internal fault currents discrimination in power transformer differential protection

M Tajdinian, H Samet - Electric power systems research, 2021 - Elsevier
Differential protection failure in discrimination of inrush and internal fault currents will impose
significant challenges and damages both on the power transformers and power systems. To …

An open-loop fundamental and harmonic phasor estimator for single-phase voltage signals

MV Reddy, R Sodhi - IEEE Transactions on Industrial …, 2019 - ieeexplore.ieee.org
This article proposes a novel technique for fundamental and selective harmonic phasor
estimation of a single-phase voltage signal based on open-loop voltage signal processing …

Removal of system and CT decaying DC component in fault signal using selective interval integration

S Jamali, H Zamani - IEEE Transactions on Power Delivery, 2021 - ieeexplore.ieee.org
The fundamental current component at the secondary side of current transformer (CT) is
often accompanied with decaying direct current (DC) component produced by the system …

Two modified DFT‐based algorithms for fundamental phasor estimation

S Afrandideh, MR Arabshahi… - IET Generation …, 2022 - Wiley Online Library
The discrete Fourier transform (DFT) is a powerful phasor estimation algorithm
conventionally used in digital relaying applications. The DFT‐based phasor estimation is …

An improved morphological transform filter for fundamental frequency phasor measurement of power system

C Mo, TY Ji, G Mei, LL Zhang, QH Wu - Measurement, 2023 - Elsevier
The fundamental frequency phasor measurement method based on Fourier transform is
affected by the decaying DC offset in fault current. To reduce this effect, a morphological …

A new DFT-based frequency estimation algorithm for protection devices under normal and fault conditions

SSK Madahi, HA Abyaneh, CA Nucci… - International Journal of …, 2022 - Elsevier
Frequency is one of the essential parameters for monitoring, control, and protection in power
systems. Some protection devices use frequency for deciding under various conditions of …

An innovative method to eliminate multiple exponentially decaying DC components based on the discrete Fourier transform in the numerical distance relay

M Parpaei, HA Abyaneh… - … Transmission & Distribution, 2022 - Wiley Online Library
Exponentially decaying direct current (EDDC) components in the faulted current of a power
system can result in an imprecise estimation of the fundamental frequency component …

A 90-degree phasor rotator and a fast decaying DC calculation method suitable for the situation where a fault occurs in out-of-step oscillation process

S Zhang - Electric Power Systems Research, 2024 - Elsevier
The decaying DC calculation is an important task for the implementation of fault detection
and transient protection in power system. Speed and precision are its fundamental …