[图书][B] Measurement and detection of radiation

N Tsoulfanidis, S Landsberger - 2021 - taylorfrancis.com
As useful to students and nuclear professionals as its popular predecessors, this fifth edition
provides the most up-to-date and accessible introduction to radiation detector materials …

A comprehensive survey of readout strategies for SiPMs used in nuclear imaging systems

S Hatefi Hesari, MA Haque, N McFarlane - Photonics, 2021 - mdpi.com
Silicon photomultipliers (SiPMs) offer advantages such as lower relative cost, smaller size,
and lower operating voltages compared to photomultiplier tubes. A SiPM's readout circuit …

GAMMA: A 16-channel spectroscopic ASIC for SiPMs readout with 84-dB dynamic range

L Buonanno, D Di Vita, M Carminati… - IEEE Transactions on …, 2021 - ieeexplore.ieee.org
Gain amplitude modulation multichannel ASIC (GAMMA) is a 16-channel application
specified integrated circuit (ASIC), designed in 0.35-technology to read the charge provided …

A directional gamma-ray spectrometer with microcontroller-embedded machine learning

L Buonanno, D Di Vita, M Carminati… - IEEE Journal on …, 2020 - ieeexplore.ieee.org
The enhancement of a compact gamma-ray detection module for spectroscopy and imaging
with machine learning for directional sensitivity is presented. In particular this development …

Experimental validation of a spectroscopic gamma-ray detector based on a LaBr3 scintillator towards real-time dose monitoring in BNCT

A Caracciolo, D Di Vita, L Buonanno… - Nuclear Instruments and …, 2022 - Elsevier
We report the experimental validation of a detection module based on a LaBr 3 (Ce+ Sr)
scintillator crystal, read by a matrix of Silicon Photomultipliers (SiPMs), for the development …

Gamma ray detection performance of newly developed MAPD-3NM-II photosensor with LaBr3(Ce) crystal

M Holik, F Ahmadov, A Sadigov, G Ahmadov… - Scientific Reports, 2022 - nature.com
This paper presents the gamma-ray detection performance of the newly developed MAPD-
3NM-II type SiPM sensor array (4× 4) with LaBr 3 (Ce) scintillator. The gamma-ray spectra of …

BeNEdiCTE (Boron Neutron Capture): a versatile gamma-ray detection module for boron neutron capture therapy

A Caracciolo, L Buonanno, D Di Vita… - … on Radiation and …, 2022 - ieeexplore.ieee.org
We present a gamma-ray detection module for quantifying the boron neutron capture events
that occur in the boron neutron capture therapy (BNCT) and neutron capture enhanced …

A 144-SiPM 3” LaBr3 readout module for PMTs replacement in Gamma spectroscopy

D Di Vita, L Buonanno, F Canclini, G Ticchi… - Nuclear Instruments and …, 2022 - Elsevier
A SiPM-based gamma-ray detection module for substituting bulky Photomultiplier Tubes in
the readout of large scintillation crystals is presented. The system can be coupled to …

A gamma-ray spectrometer based on MAPD-3NM-2 and LaBr3(ce) and LSO scintillators for hydrogen detection on planetary surfaces

F Ahmadov, A Sadigov, YY Bacherikov… - Scientific Reports, 2025 - nature.com
The presented work is dedicated to the detection of hydrogen, using detectors based on a
MAPD (Micropixel Avalanche Photodiode) array based on new MAPD-3NM-2 type …

Characterization of a Sr co-doped LaBr3:(Ce) detector for γ-ray spectroscopy

S Panwar, I Mazumdar, R Sariyal, V Ranga… - Nuclear Instruments and …, 2020 - Elsevier
In this paper we report about thorough characterization of Sr 2+ co-doped LaBr 3: Ce single
crystal of dimensions 1. 5′′× 1. 5′′. The properties studied include energy resolution …