Polysaccharides in contact lenses: from additives to bulk materials

Q Zhu, Q Zhang, DY Fu, G Su - Carbohydrate Polymers, 2023 - Elsevier
As the number of applications has increased, so has the demand for contact lenses comfort.
Adding polysaccharides to lenses is a popular way to enhance comfort for wearers …

[HTML][HTML] Roughness of the plasma membrane as an independent morphological parameter to study RBCs: a quantitative atomic force microscopy investigation

M Girasole, G Pompeo, A Cricenti… - … et Biophysica Acta (BBA …, 2007 - Elsevier
A novel approach to the study of RBCs based on the collection of three-dimensional high-
resolution AFM images and on the measure of the surface roughness of their plasma …

An introduction to intraocular lenses: material, optics, haptics, design and aberration

R Bellucci - Cataract, 2013 - torrossa.com
Several intraocular lens (IOL) materials and types are currently available. Polymethyl
methacrylate IOLs used to be the gold standard, but the inability of folding limits their use to …

Evaluation of clarity characteristics in a new hydrophobic acrylic IOL in comparison to commercially available IOLs

L Werner, I Thatthamla, M Ong, H Schatz… - Journal of Cataract & …, 2019 - Elsevier
Purpose To perform in vitro assessments of surface haze and roughness, subsurface
nanoglistenings (SSNGs), and glistenings of a new hydrophobic acrylic intraocular lens …

Analysis of intraocular lens surface adhesiveness by atomic force microscopy

M Lombardo, G Carbone, G Lombardo… - Journal of Cataract & …, 2009 - Elsevier
PURPOSE: To analyze intraocular lens (IOL) optic surface adhesiveness using atomic force
microscopy (AFM). SETTING: LiCryL Laboratory, University of Calabria, Rende, Italy …

Современные стандарты хирургии катаракты с имплантацией интраокулярной линзы. Обзор литературы

АВ Терещенко, ЮА Белый, СК Демьянченко… - Рефракционная …, 2010 - elibrary.ru
В обзоре освещены вопросы, касающиеся актуальных направлений имплантологии,
современных концепций и решений, направленных на оптимизацию оптических …

A laboratory evaluation of nozzle tip damage in four generations of intraocular lens injector systems using a self-developed damage scale

H Fang, L Zhang, S Schickhardt, PR Merz, W Yan… - Scientific Reports, 2022 - nature.com
During intraocular lens (IOL) implantation it is not uncommon for the injector's nozzle-tip to
get damaged. However, the damage has not been systematically described or evaluated …

[HTML][HTML] Twelve-months follow-up postmarket study of a hydrophobic intraocular lens using a preloaded automated injector in an Indian population

JS Titiyal, SK Basak, N Shetty, U Mathur… - Clinical …, 2022 - ncbi.nlm.nih.gov
Twelve-Months Follow-Up Postmarket Study of a Hydrophobic Intraocular Lens Using a
Preloaded Automated Injector in an Indian Population - PMC Back to Top Skip to main content …

Design of adjustable multifocal diffractive optical elements with an improved smooth phase profile by continuous variable curve with multi-subperiods method

B Dong, Y Yang, Y Liu, C Li, C Yang, C Xue - Optics Express, 2023 - opg.optica.org
Multifocal diffractive optical elements (MDOEs), which produce arbitrary light distribution, are
widely used in lightweight and compact optical systems. MDOEs that are combined with …

Surface modification of polymethyl methacrylate intraocular lenses by plasma for improvement of antithrombogenicity and transmittance

L Zhang, D Wu, Y Chen, X Wang, G Zhao, H Wan… - Applied surface …, 2009 - Elsevier
To improve antithrombogenicity and reduce ultraviolet transmittance, polymethyl
methacrylate intraocular lenses (PMMA IOLs) were pretreated with Ar plasma and combined …