Comprehensive optimization of the tripolar concentric ring electrode based on its finite dimensions model and confirmed by finite element method modeling

O Makeyev, Y Ye-Lin, G Prats-Boluda… - Sensors, 2021 - mdpi.com
The optimization performed in this study is based on the finite dimensions model of the
concentric ring electrode as opposed to the negligible dimensions model used in the past …

Looking for optimal concentric ring electrodes: influence of design aspects on their performance

J Garcia-Casado, Y Ye-Lin… - Measurement …, 2023 - iopscience.iop.org
Concentric ring electrodes (CREs) allow improved spatial resolution, reduced crosstalk and
interference, and increased bandwidth in the sensing of bioelectrical activity. A wide variety …

Comparing optimal and commercially available bipolar and tripolar concentric ring electrode configurations using finite element method modeling based on their finite …

O Makeyev, Y Ye-Lin, G Prats-Boluda… - 2022 IEEE Sensors …, 2022 - ieeexplore.ieee.org
While finite element method modeling has been used to compare bipolar and tripolar
concentric ring electrode configurations in the past it was based on the simplistic negligible …

Time and Frequency Domain Synchrony of Current and Optimal Laplacian Estimates via T-Lead Electrodes on Human Electroencephalogram Data

A Benally, O Makeyev, Y Ye-Lin… - 2024 IEEE Sensors …, 2024 - ieeexplore.ieee.org
Lead is a commercial tripolar concentric ring electrode designed for noninvasive
electrophysiological measurement applications. Utilizing the unique ability of concentric ring …

Finite element method modeling to confirm the results of comprehensive optimization of the tripolar concentric ring electrode based on its finite dimensions model

O Makeyev, Y Ye-Lin, G Prats-Boluda… - 2021 43rd Annual …, 2021 - ieeexplore.ieee.org
Concentric ring electrodes are noninvasive and wearable sensors for electrophysiological
measurement capable of estimating the surface Laplacian (second spatial derivative of …

Bio-Z-Based Feedback-Controlled External Diaphragm Pacing System

Z Zhou, W Wang, R Yang, Y Wang… - IEEE Transactions on …, 2023 - ieeexplore.ieee.org
In this brief, a bio-impedance (Bio-Z) based closed-loop control scheme is proposed for a
wearable external diaphragm pacing (EDP) system. EDP delivers functional electrical …

Assessment of the Non-linear Response of the fSampEn on Simulated EMG Signals

L Estrada-Petrocelli, M Lozano-García… - 2021 43rd Annual …, 2021 - ieeexplore.ieee.org
Fixed sample entropy (fSampEn) is a promising technique for the analysis of respiratory
electromyographic (EMG) signals. Its use has shown outperformance of amplitude-based …

Solving the Inter-Ring Distances Optimization Problem for Pentapolar and Sextopolar Concentric Ring Electrodes Based on the Negligible Dimensions Model of the …

O Makeyev, A Lee, A Begay - Engineering Proceedings, 2021 - mdpi.com
Concentric ring electrodes are noninvasive and wearable sensors for electrophysiological
measurement capable of estimating the surface Laplacian (second spatial derivative of …

[PDF][PDF] Concentric Ring Tattoo Electrodes for Biosignal Recordings.

G Prats-Boluda, E Garcia-Breijo… - BIOSTEC (1), 2024 - researchgate.net
Non-invasive bioelectrical recordings utilize monopolar or bipolar disc electrodes. However,
these electrodes suffer from poor spatial resolution, leading to susceptibility to physiological …