Monte Carlo methods for device simulations in radiation therapy

H Park, H Paganetti, J Schuemann… - Physics in Medicine & …, 2021 - iopscience.iop.org
Monte Carlo (MC) simulations play an important role in radiotherapy, especially as a method
to evaluate physical properties that are either impossible or difficult to measure. For …

Photonic-Crystal Scintillators: Molding the Flow of Light to Enhance X-Ray and -Ray Detection

Y Kurman, A Shultzman, O Segal, A Pick, I Kaminer - Physical Review Letters, 2020 - APS
Scintillators are central for detection of γ-ray, x-ray, and high energy particles in various
applications, all seeking higher scintillation yield and rate. However, these are limited by the …

Evaluation of solid-state detectors in medical imaging with fuzzy PROMETHEE

I Ozsahin, T Sharif, DU Ozsahin… - Journal of …, 2019 - iopscience.iop.org
Solid-state semiconductor detectors are radiation detectors which employs a semiconductor
material as the detecting medium. These detectors produce pulse of electric current by …

Simulation of the expected performance of a seamless scanner for brain PET based on highly pixelated CdTe detectors

E Mikhaylova, G De Lorenzo… - IEEE transactions on …, 2013 - ieeexplore.ieee.org
The aim of this work is the evaluation of the design for a nonconventional PET scanner, the
voxel imaging PET (VIP), based on pixelated room-temperature CdTe detectors yielding a …

[图书][B] Radiation detectors for medical imaging

JS Iwanczyk - 2015 - books.google.com
Radiation Detectors for Medical Imaging discusses the current state of the art and future
prospects of photon-counting detectors for medical imaging applications. Featuring …

Evaluation of list-mode ordered subset expectation maximization image reconstruction for pixelated solid-state compton gamma camera with large number of …

M Kolstein, G De Lorenzo… - Journal of …, 2014 - iopscience.iop.org
Abstract The Voxel Imaging PET (VIP) Pathfinder project intends to show the advantages of
using pixelated solid-state technology for nuclear medicine applications. It proposes designs …

Evaluation of Compton gamma camera prototype based on pixelated CdTe detectors

Y Calderón, M Chmeissani, M Kolstein… - Journal of …, 2014 - iopscience.iop.org
A proposed Compton camera prototype based on pixelated CdTe is simulated and
evaluated in order to establish its feasibility and expected performance in real laboratory …

[图书][B] Design, development, and modeling of a compton camera tomographer based on room temperature solid statepixel detector

Y Calderón, MP Casado Lechuga - 2014 - ddd.uab.cat
Since the discovery of the X-rays in 1895 and their first medical application one year later,
many different medical imaging techniques have been developed. Emission tomography is …

Evaluation of Origin Ensemble algorithm for image reconstruction for pixelated solid-state detectors with large number of channels

M Kolstein, G De Lorenzo, E Mikhaylova… - Journal of …, 2013 - iopscience.iop.org
Abstract The Voxel Imaging PET (VIP) Pathfinder project intends to show the advantages of
using pixelated solid-state technology for nuclear medicine applications. It proposes designs …

First results of a highly granulated 3D CdTe detector module for PET

M Chmeissani, M Kolstein… - Physics in Medicine …, 2018 - iopscience.iop.org
We present the performance of a highly granulated 3D detector module for PET, consisting
of a stack of pixelated CdTe detectors. Each detector module has 2 cm× 2 cm× 2 cm of CdTe …