High rate of radiolucent lines following the cemented original design of the ATTUNE total knee arthroplasty: a systematic review and meta-analysis

AD Prodromidis, GD Chloros… - The Bone & Joint …, 2023 - boneandjoint.org.uk
Aims Loosening of components after total knee arthroplasty (TKA) can be associated with
the development of radiolucent lines (RLLs). The aim of this study was to assess the rate of …

Application of bone cement directly to the implant in primary total knee arthroplasty. Short-term radiological and clinical follow-up of two different cementing techniques

LA Holzer, MA Finsterwald, S Sobhi, CW Jones… - Archives of Orthopaedic …, 2024 - Springer
Purpose This study aimed to optimize cement application techniques in fully cemented
primary total knee arthroplasty (TKA) by comparing the effects of two different approaches …

Medialized Dome and Anatomic Onlay Patella Designs in the Modern Posterior Stabilized Rotating Platform Total Knee Arthroplasty Demonstrate No Clinical or …

S Sobhi, MA Finsterwald, S Häckel, LA Holzer… - The Journal of …, 2024 - Elsevier
Background A successful outcome after total knee arthroplasty (TKA) includes the
restoration of patellofemoral function. Modern patella component designs in TKA include a …

Is there an increased revision rate due to early tibial component loosening with a modern total knee arthroplasty design? A retrospective analysis from a large volume …

BH van Duren, J France, R Berber, HE Matar… - Arthroplasty, 2024 - Springer
Abstract Background The Attune TKR was introduced in 2011 as a successor to its predicate
design The PFC Sigma. However, following reports of early failures, there are ongoing …

Prevalence and clinical impact of radiographic sclerotic lines adjacent to cementless tibial stems in revision total knee arthroplasty: a long-term follow-up study

A Greenberg, D Cohen, S Ekhtiari… - European Journal of …, 2024 - Springer
Intramedullary stem extensions are typically added to the femoral and tibial components
during revision total knee arthroplasty (TKA) to augment fixation of the components and …

Development of an innovative in vivo model of PJI treated with DAIR

H Poilvache, F Van Bambeke, O Cornu - Frontiers in medicine, 2022 - frontiersin.org
Introduction Prosthetic Joint Infection (PJI) are catastrophic complications of joint
replacement. Debridement, implant retention, and antibiotic therapy (DAIR) is the usual …

Is TKA femoral implant stability improved by pressure applied cement? a comparison of 2 cementing techniques

M Schonhoff, NA Beckmann, M Schwarze… - BMC Musculoskeletal …, 2023 - Springer
Background The majority of knee endoprostheses are cemented. In an earlier study the
effects of different cementing techniques on cement penetration were evaluated using a …

Tibial tray debonding from the cement mantle is associated with deformation of the backside of polyethylene tibial inserts

RM Bhalekar, ME Nargol, N Shyam… - The Bone & Joint …, 2021 - boneandjoint.org.uk
Aims The aim of this study was to investigate whether wear and backside deformation of
polyethylene (PE) tibial inserts may influence the cement cover of tibial trays of explanted …

[HTML][HTML] Aseptic tibial loosening: Radiographic identification remains a diagnostic dilemma

CT Crellin, JS Pennings, SM Engstrom… - Journal of Orthopaedic …, 2023 - Elsevier
Introduction Aseptic tibial loosening following total knee arthroplasty (TKA) can be
challenging to diagnose radiographically. Surgeons often face the clinical scenario of …

[PDF][PDF] Der Vergleich von Single-Radius mit Multi-Radius Knie-Endoprothesen in Bezug auf Beweglichkeit, Patientenzufriedenheit und Schmerz

C Dolls - 2023 - scholar.archive.org
Abstrakt Dolls Christopher Der Vergleich von Single-Radius mit Multi-Radius Knie-
Endoprothesen in Bezug auf Beweglichkeit, Patientenzufriedenheit und Schmerz Einleitung …