International consensus on use of continuous glucose monitoring

T Danne, R Nimri, T Battelino, RM Bergenstal… - Diabetes …, 2017 - Am Diabetes Assoc
Measurement of glycated hemoglobin (HbA1c) has been the traditional method for
assessing glycemic control. However, it does not reflect intra-and interday glycemic …

Benefits and limitations of MARD as a performance parameter for continuous glucose monitoring in the interstitial space

L Heinemann, M Schoemaker… - Journal of Diabetes …, 2020 - journals.sagepub.com
High-quality performance of medical devices for glucose monitoring is important for a safe
and efficient usage of this diagnostic option by patients with diabetes. The mean absolute …

Current and emerging trends in point-of-care technology and strategies for clinical validation and implementation

P Wang, LJ Kricka - Clinical chemistry, 2018 - academic.oup.com
BACKGROUND Point-of-care technology (POCT) provides actionable information at the site
of care to allow rapid clinical decision-making. With healthcare emphasis shifting toward …

Significance and reliability of MARD for the accuracy of CGM systems

F Reiterer, P Polterauer… - Journal of diabetes …, 2017 - journals.sagepub.com
Background: There is a need to assess the accuracy of continuous glucose monitoring
(CGM) systems for several uses. Mean absolute relative difference (MARD) is the measure …

Multivariable artificial pancreas for various exercise types and intensities

K Turksoy, I Hajizadeh, N Hobbs, J Kilkus… - Diabetes technology …, 2018 - liebertpub.com
Background: Exercise challenges people with type 1 diabetes in controlling their glucose
concentration (GC). A multivariable adaptive artificial pancreas (MAAP) may lessen the …

American Association of Clinical Endocrinologists and American College of Endocrinology 2016 outpatient glucose monitoring consensus statement

TS Bailey, G Grunberger, BW Bode, Y Handelsman… - Endocrine Practice, 2016 - Elsevier
Abbreviations: A1C= glycated hemoglobin AGP= ambulatory glucose profile ARD= absolute
relative difference BGM= blood glucose monitoring CGM= continuous glucose monitoring …

A new model to determine the thermal conductivity of fine-grained soils

J Bi, M Zhang, W Chen, J Lu, Y Lai - International Journal of Heat and Mass …, 2018 - Elsevier
In the study, a three-parameter model was presented to calculate the thermal conductivity at
full range of degree of saturation (S) for fine-grained soils based on the Fredlund and Xing …

A novel method to detect pressure-induced sensor attenuations (PISA) in an artificial pancreas

N Baysal, F Cameron, BA Buckingham… - Journal of diabetes …, 2014 - journals.sagepub.com
Background: Continuous glucose monitors (CGMs) provide real-time interstitial glucose
concentrations that are essential for automated treatment of individuals with type 1 diabetes …

Analytical Performance of the Factory-Calibrated Flash Glucose Monitoring System FreeStyle Libre2TM in Healthy Women

Z Jin, AE Thackray, JA King, K Deighton, MJ Davies… - Sensors, 2023 - mdpi.com
Continuous glucose monitoring (CGM) is used clinically and for research purposes to
capture glycaemic profiles. The accuracy of CGM among healthy populations has not been …

Performance evaluation of three continuous glucose monitoring systems: comparison of six sensors per subject in parallel

G Freckmann, S Pleus, M Link, E Zschornack… - 2013 - journals.sagepub.com
Background: This study is aimed at comparing the performance of three continuous glucose
monitoring (CGM) systems following the Clinical and Laboratory Standards Institute's …