Experimental performance of a direct evaporative cooler in composite climate of India

D Bishoyi, K Sudhakar - Energy and Buildings, 2017 - Elsevier
Evaporative air coolers are widely used in peak summer seasons for air conditioning in
residential and commercial building spaces. Cooling pads play a major role in cooling …

Comparative assessment of different air‐conditioning systems for nearly/net zero‐energy buildings

G Singh, R Das - International Journal of Energy Research, 2020 - Wiley Online Library
This study deals with the performance of different air‐conditioning strategies for achieving
the target of nearly/net zero energy in a medium‐scale building under various environmental …

Experimental and numerical evaluation of a two-stage indirect/thermoelectric assisted direct evaporative cooling system

Y Zhou, Z Yan, Q Dai, Y Yu - Energy Conversion and Management, 2021 - Elsevier
The performance of a novel two-stage indirect/thermoelectric assisted direct evaporative
cooling (ie IEC/TDEC) system is studied by using experimental and numerical simulation …

Performance enhancement studies on evaporative cooling using volumetric heat and mass transfer coefficients

V Naveenprabhu, M Suresh - Numerical Heat Transfer, Part A …, 2020 - Taylor & Francis
In the present work, a test facility has been set up to observe direct water–air interaction with
and without a cellulose cooling pad. Volumetric heat and mass transfer coefficients have …

Modeling and performance analysis of a hybrid-connected two-stage liquid dehumidification fresh air system based on CaCl2/LiCl double solution

D Peng, Z Cao - Applied Thermal Engineering, 2021 - Elsevier
In this paper, a novel hybrid-connected two-stage liquid dehumidification fresh air (HTLDFA)
system by combining CaCl 2 with LiCl aqueous solutions is proposed, in which the ambient …

Evaporative cooling options for building air-conditioning: A comprehensive study for climatic conditions of Multan (Pakistan)

S Noor, H Ashraf, M Sultan, ZM Khan - Energies, 2020 - mdpi.com
This study provides comprehensive details of evaporative cooling options for building air-
conditioning (AC) in Multan (Pakistan). Standalone evaporative cooling and standalone …

A feasibility assessment of single to multi/hybrid evaporative coolers for building air-conditioning across diverse climates in India

VV Rao, SP Datta - Applied Thermal Engineering, 2020 - Elsevier
This paper assesses the potential of direct evaporative cooling (DEC), indirect evaporative
cooling (IEC), direct expansion system (DX) and their different combinations (IEC-DEC, DEC …

Experimental investigation of desiccant dehumidification cooling system for climatic conditions of multan (pakistan)

M Aleem, G Hussain, M Sultan, T Miyazaki… - Energies, 2020 - mdpi.com
In this study, experimental apparatus of desiccant dehumidification was developed at lab-
scale, using silica gel as a desiccant material. Experimental data were obtained at various …

Theoretical performance analysis of window air conditioner combined with evaporative cooling for better indoor thermal comfort and energy saving

AK Dhamneya, SPS Rajput, A Singh - Journal of Building Engineering, 2018 - Elsevier
In hot & dry climate conditions, the humidity level of the supplied air wrt the conditioned
space is not sufficient to meet the required human comfort. Such extreme climate, which …

Thermo-economic assessment of air conditioner utilizing direct evaporative cooling: A comprehensive analysis

SK Gupta, BB Arora, A Arora - International Journal of Refrigeration, 2024 - Elsevier
As concerns regarding energy consumption and environmental impact continue to grow, the
need for efficient and sustainable cooling technologies becomes increasingly significant …