Deep inspiration breath hold and respiratory gating strategies for reducing organ motion in radiation treatment

GS Mageras, E Yorke - Seminars in radiation oncology, 2004 - Elsevier
We examine 2 strategies for reducing respiration-induced organ motion in radiation
treatment: deep inspiration breath hold (DIBH) and respiratory gating. DIBH is a controlled …

Adaptive radiotherapy of head and neck cancer

P Castadot, JA Lee, X Geets, V Grégoire - Seminars in radiation oncology, 2010 - Elsevier
Intensity-modulated radiation therapy (IMRT) in head and neck (H&N) cancer has the
capability to generate steep dose gradients, leading to an improved therapeutic index. IMRT …

Flat-panel cone-beam computed tomography for image-guided radiation therapy

DA Jaffray, JH Siewerdsen, JW Wong… - International Journal of …, 2002 - Elsevier
Purpose: Geometric uncertainties in the process of radiation planning and delivery constrain
dose escalation and induce normal tissue complications. An imaging system has been …

[图书][B] Handbook of radiotherapy physics: theory and practice

P Mayles, A Nahum, JC Rosenwald - 2007 - taylorfrancis.com
From background physics and biological models to the latest imaging and treatment
modalities, the Handbook of Radiotherapy Physics: Theory and Practice covers all …

The management of imaging dose during image‐guided radiotherapy: report of the AAPM Task Group 75

MJ Murphy, J Balter, S Balter, JA BenComo Jr… - Medical …, 2007 - Wiley Online Library
Radiographic image guidance has emerged as the new paradigm for patient positioning,
target localization, and external beam alignment in radiotherapy. Although widely varied in …

[图书][B] Intensity-modulated radiation therapy

S Webb - 2015 - taylorfrancis.com
Clinical conformal radiotherapy is the holy grail of radiation treatment and is now becoming
a reality through the combined efforts of physical scientists and engineers, who have …

Accuracy of finite element model‐based multi‐organ deformable image registration

KK Brock, MB Sharpe, LA Dawson, SM Kim… - Medical …, 2005 - Wiley Online Library
As more pretreatment imaging becomes integrated into the treatment planning process and
full three‐dimensional image‐guidance becomes part of the treatment delivery the need for …

Multi-mode cone beam CT radiotherapy simulator and treatment machine with a flat panel imager

EG Shapiro, EJ Seppi, JM Pavkovich, P Munro… - US Patent …, 2012 - Google Patents
(57) ABSTRACT A multi-mode cone beam computed tomography radio therapy simulator
and treatment machine is disclosed. The radiotherapy simulator and treatment machine both …

Multi-mode cone beam CT radiotherapy simulator and treatment machine with a flat panel imager

EG Shapiro, EJ Seppi, JM Pavkovich, P Munro… - US Patent …, 2011 - Google Patents
5,039,867 A 8, 1991 Nishihara et al. 5,080,100 A 1, 1992 Trotel 5,099,505 A 3/1992 Seppi et
al. 5,117,445 A 5/1992 Seppi et al. 5,168,532 A 12/1992 Seppi et al. 5,247,555 A 9, 1993 …

Comparison of localization performance with implanted fiducial markers and cone-beam computed tomography for on-line image-guided radiotherapy of the prostate

DJ Moseley, EA White, KL Wiltshire, T Rosewall… - International Journal of …, 2007 - Elsevier
Purpose: The aim of this work was to assess the accuracy of kilovoltage (kV) cone-beam
computed tomography (CBCT)–based setup corrections as compared with orthogonal …