The silicon photomultiplier: fundamentals and applications of a modern solid-state photon detector

S Gundacker, A Heering - Physics in Medicine & Biology, 2020 - iopscience.iop.org
The silicon photomultiplier (SiPM) is an established device of choice for a variety of
applications, eg in time of flight positron emission tomography (TOF-PET), lifetime …

Prompt-gamma monitoring in hadrontherapy: A review

J Krimmer, D Dauvergne, JM Létang, É Testa - Nuclear Instruments and …, 2018 - Elsevier
Secondary radiation emission induced by nuclear reactions is correlated to the path of ions
in matter. Therefore, such penetrating radiation can be used for in vivo control of …

Range verification methods in particle therapy: underlying physics and Monte Carlo modeling

AC Kraan - Frontiers in oncology, 2015 - frontiersin.org
Hadron therapy allows for highly conformal dose distributions and better sparing of organs-
at-risk, thanks to the characteristic dose deposition as function of depth. However, the quality …

Range assessment in particle therapy based on prompt γ-ray timing measurements

C Golnik, F Hueso-González, A Müller… - Physics in Medicine …, 2014 - iopscience.iop.org
Proton and ion beams open up new vistas for the curative treatment of tumors, but adequate
technologies for monitoring the compliance of dose delivery with treatment plans in real time …

Compton imaging for medical applications

H Tashima, T Yamaya - Radiological Physics and Technology, 2022 - Springer
Compton imaging exploits inelastic scattering, known as Compton scattering, using a
Compton camera consisting of a scatterer detector in the front layer and an absorber …

Development of a Compton camera for medical applications based on silicon strip and scintillation detectors

J Krimmer, JL Ley, C Abellan, JP Cachemiche… - Nuclear Instruments and …, 2015 - Elsevier
A Compton camera is being developed for the purpose of ion-range monitoring during
hadrontherapy via the detection of prompt-gamma rays. The system consists of a scintillating …

Medical applications of silicon photomultipliers

MG Bisogni, A Del Guerra, N Belcari - Nuclear instruments and methods in …, 2019 - Elsevier
Silicon photomultipliers (SiPMs) are becoming the reference photodetectors in many fields.
In medicine they are slowly replacing photomultiplier tubes and avalanche photodiodes in …

A high sensitivity Cherenkov detector for prompt gamma timing and time imaging

M Jacquet, S Ansari, ML Gallin-Martel, A André… - Scientific Reports, 2023 - nature.com
We recently proposed a new approach for the real-time monitoring of particle therapy
treatments with the goal of achieving high sensitivities on the particle range measurement …

Development of a Compton camera for prompt-gamma medical imaging

S Aldawood, PG Thirolf, A Miani, M Böhmer… - Radiation Physics and …, 2017 - Elsevier
A Compton camera-based detector system for photon detection from nuclear reactions
induced by proton (or heavier ion) beams is under development at LMU Munich, targeting …

Short-lived positron emitters in beam-on PET imaging during proton therapy

P Dendooven, HJT Buitenhuis, F Diblen… - Physics in Medicine …, 2015 - iopscience.iop.org
The only method for in vivo dose delivery verification in proton beam radiotherapy in clinical
use today is positron emission tomography (PET) of the positron emitters produced in the …