Evaluating medical device and material thrombosis under flow: current and emerging technologies

JK Hong, L Gao, J Singh, T Goh, AM Ruhoff… - Biomaterials …, 2020 - pubs.rsc.org
Although blood-contacting medical devices are used widely, blood clot formation
(thrombosis) leads to device failure and potentially catastrophic adverse thrombotic events …

Hemolysis during short-term mechanical circulatory support: from pathophysiology to diagnosis and treatment

T Balthazar, J Bennett… - Expert review of medical …, 2022 - Taylor & Francis
Introduction Despite advances in heart failure therapies and percutaneous coronary
interventions, survival for cardiogenic shock remains poor. Percutaneous ventricular assist …

Paravalvular leaks—from diagnosis to management

S Bernard, E Yucel - Current treatment options in cardiovascular medicine, 2019 - Springer
Purpose of review As the number of surgical and transcatheter valve replacements continue
to increase in the aging population, so does the incidence of paravalvular leak (PVL). Given …

[HTML][HTML] Cardiovascular magnetic resonance and transesophageal echocardiography in patients with prosthetic valve paravalvular leaks: towards an accurate …

M Haberka, M Malczewska, P Pysz, M Kozłowski… - Journal of …, 2021 - Elsevier
Background Objective assessment of prosthetic paravalvular leak (PVL) is complex and
challenging even in transesophageal echocardiography (TEE). Our aim was to assess the …

Hemocompatibility studies in nanotoxicology: Hemolysis or eryptosis?(A review)

A Tkachenko - Toxicology in Vitro, 2024 - Elsevier
Hemocompatibility evaluation is an important step in nanotoxicological studies. It is
generally accepted that nanomaterials promote lysis of erythrocytes, blood clotting, alter …

Long-term evaluation of TTK Chitra™ heart valve prosthesis—a retrospective-prospective cohort study

PK Varma, M Vijayakumar, GS Bhuvaneshwar… - Indian Journal of …, 2023 - Springer
Abstract Purpose The TTK Chitra™ heart valve has more than 1, 40,000 implantations so far,
but no long-term data has been published. This study aims to provide long-term results of …

Mechanical circulatory support in patients with cardiogenic shock

M Alkhouli, M Osman, MFA Elsisy, A Kawsara… - … Treatment Options in …, 2020 - Springer
Purpose of review To provide a contemporary concise overview of the currently available
mechanical circulatory support (MCS) devices and the emerging concepts in the …

Evaluation and Management of Mechanical Heart Valve Dysfunction and Thrombosis

G Parizher, A Ali, PC Cremer - Current Cardiology Reports, 2024 - Springer
Abstract Purpose of Review Dysfunction and thrombosis of mechanical heart valves,
although uncommon, represents a challenge that requires multidisciplinary expertise for …

Stent deformation in a sutureless aortic valve bioprosthesis: a pilot observational analysis using imaging and three-dimensional modelling

A Aljalloud, K Spetsotaki, L Tewarie… - European Journal of …, 2022 - academic.oup.com
OBJECTIVES The goal of this analysis of the Perceval aortic bioprosthesis was to
investigate the ovalization/deformation of the Perceval prosthesis stent after implantation …

An approach for material selection for bone staple (an orthopaedic implant) using GRA and Fuzzy logic

N Sanghvi, D Vora, E Charaya, J Patel… - Materials Today …, 2021 - Elsevier
This paper aims to develop a mathematical framework to compare suitability of multiple
candidate biomaterials for the manufacture of bone staples. This task is essentially a …