An overview of DC component generation, detection and suppression for grid-connected converter systems

B Long, M Zhang, Y Liao, L Huang, KT Chong - IEEE Access, 2019 - ieeexplore.ieee.org
Transformerless grid-connected distributed photovoltaic (PV) systems (TGCDPVs) has the
merits of high efficiency, small size, and low cost, draws great interest in recent years …

Overview of transformerless photovoltaic grid-connected inverters

H Xiao - IEEE Transactions on Power Electronics, 2020 - ieeexplore.ieee.org
Transformerless grid-connected inverters (TLI) feature high efficiency, low cost, low volume,
and weight due to using neither line-frequency transformers nor high-frequency …

A review of minimisation of output DC current component methods in single-phase grid-connected inverters PV applications

F Berba, D Atkinson… - 2012 2nd International …, 2012 - ieeexplore.ieee.org
Nowadays, it is a general trend to increase the Distribution Generator (DG) based on
renewable energy such as photovoltaic (PV) system. This generator can affect the grid by …

A novel control strategy of suppressing DC current injection to the grid for single-phase PV inverter

G He, D Xu, M Chen - IEEE transactions on power electronics, 2014 - ieeexplore.ieee.org
Photovoltaic (PV) inverters without the isolation transformer become more attractive due to
higher efficiency and lower weight. However, it may have dc offset current problem and is …

A DC offset current compensation strategy in transformerless grid-connected power converters

G Buticchi, E Lorenzani… - IEEE Transactions on …, 2011 - ieeexplore.ieee.org
A line frequency transformer is usually employed in grid-connected power converters, from
both renewable and traditional energy sources, in order to suppress the DC current …

Direct current offset controller for transformerless single-phase photovoltaic grid-connected inverters

L Bowtell, A Ahfock - IET Renewable Power Generation, 2010 - IET
Limitation of direct current (DC) injection into the alternating current (AC) network is an
important operational requirement for grid-connected photovoltaic (PV) systems. One way to …

Approach to low-cost prevention of DC injection in transformerless grid connected inverters

WM Blewitt, DJ Atkinson, J Kelly, RA Lakin - IET Power Electronics, 2010 - IET
With the growing popularity of distributed generation, there are concerns over the effects that
distributed generators may have on power quality. One highly important aspect often …

An adaptive method for DC current reduction in totem pole power factor correction converters

P Amiri, W Eberle, D Gautam… - IEEE Transactions on …, 2021 - ieeexplore.ieee.org
Enabled by improved wideband gap semiconductor devices, the bridgeless totem pole
power factor correction (PFC) converter is becoming an increasingly popular topology for …

Coupled-inductor-based DC current measurement technique for transformerless grid-tied inverters

A Abdelhakim, P Mattavelli, D Yang… - IEEE Transactions on …, 2017 - ieeexplore.ieee.org
Grid-tied photovoltaic inverters must fulfill several requirements, including high efficiency
and reduced cost and complexity of the overall system. Hence, transformerless operation is …

A novel DC current injection suppression method for three-phase grid-connected inverter without the isolation transformer

M Chen, D Xu, T Zhang, K Shi, G He… - IEEE Transactions on …, 2018 - ieeexplore.ieee.org
Due to current sensor errors, tolerance of power switching devices, and asymmetry of PWM
gating driving pulses, grid-connected inverters without isolation transformer usually have …