Real‐time control of shunt active power filter under distorted grid voltage and unbalanced load condition using self‐tuning filter

S Biricik, S Redif, ÖC Özerdem… - IET Power …, 2014 - Wiley Online Library
In this paper, an alternative control method is proposed to improve the harmonic
suppression efficiency of the active power filter in a distorted and an unbalanced power …

Operation of three-level inverter-based shunt active power filter under nonideal grid voltage conditions with dual fundamental component extraction

Y Hoon, MAM Radzi, MK Hassan… - IEEE Transactions on …, 2017 - ieeexplore.ieee.org
In this paper, a new reference current generation method is proposed for effective harmonics
mitigation and reactive power compensation of three-level neutral-point diode clamped …

A dual fundamental current extraction controller for DSTATCOM in the distribution system for power quality improvement under non-ideal source voltage condition

A Ram, PR Sharma, RK Ahuja… - … Power Components and …, 2023 - Taylor & Francis
Most of the controllers often fail to work properly when encountered with power quality (PQ)
issues like unbalanced and distorted grid voltage conditions in three-phase distribution …

New hybrid active power filter for harmonic current suppression and reactive power compensation

S Biricik, OC Ozerdem, S Redif… - International Journal of …, 2016 - Taylor & Francis
In the case of undistorted and balanced grid voltages, low ratio shunt active power filters
(APFs) can give unity power factors and achieve current harmonic cancellation. However …

Performance improvement of shunt active power filter based on indirect control with a new robust phase-locked loop

A Chemidi, MC Benhabib… - Electrical Engineering & …, 2022 - eie.khpi.edu.ua
Introduction. Since the development of the first active power filter (APF) in 1976, many efforts
have been focused on improving the performances of the APF control as the number of …

Improved harmonic suppression efficiency of single-phase APFs in distorted distribution systems

S Biricik, S Redif, SK Khadem… - International Journal of …, 2016 - Taylor & Francis
In this study, a control method is proposed to improve the harmonic suppression efficiency of
the single-phase active power filter in a distorted power system to suppress current …

Control of the shunt active power filter under non-ideal grid voltage and unbalanced load conditions

S Biricik, S Redif, OC Ozerdem… - 2013 48th International …, 2013 - ieeexplore.ieee.org
In this study a new method is proposed in order to improve the harmonic suppression
efficiency of Active Power Filter for the problems caused by the distorted and unbalanced …

Generalized design of shunt active power filter with output LCL filter

R Hou, J Wu, Y Liu, D Xu - Elektronika ir Elektrotechnika, 2014 - eejournal.ktu.lt
This paper analyses the characteristics of LCL filter in active power filter (APF) and provides
an accurate formula to determine the resonant frequency of system. Based on a single …

Compensation based on active power filters–the cost minimization

M Maciążek, D Grabowski, M Pasko… - Applied Mathematics and …, 2015 - Elsevier
The paper deals with the problem of power quality and its solution. Passive or active
compensators are usually used to reduce distortions of voltage and current waveforms …

Control of the single phase parallel active filter under weak grid voltages

S Biricik, S Redif, SK Khadem… - 2014 IEEE 5th …, 2014 - ieeexplore.ieee.org
In this study, a control method is proposed to improve the harmonic suppression efficiency of
the single phase active power filter in a distorted power system environment. Here, we …