Length and refractive index measurement by Fourier transform interferometry and frequency comb spectroscopy

P Balling, P Mašika, P Křen… - … Science and Technology, 2012 - iopscience.iop.org
In this paper we describe the progress we have made in our simultaneous length
measurement and the femtosecond comb interferometric spectroscopy in a conventional …

Double ended frequency-scanning heterodyne interferometer for absolute length measurement of opaque blocks

XH Li, BJ Wang, LH Ai, SQ Yang, QL Wang, Q Liu - Optics Communications, 2024 - Elsevier
A new contactless method based on frequency-scanning heterodyne interferometry is
proposed to measure the absolute length of opaque blocks with fragile reflective surfaces …

[HTML][HTML] The influence of key characteristic parameters on performance of optical fiber Fabry–Perot temperature sensor

F Zhang, N Zhao, Q Lin, Z Wu, B Tian, P Shi, P Yang… - AIP Advances, 2020 - pubs.aip.org
Extrinsic optical fiber Fabry–Perot (F–P) high temperature sensors using Al 2 O 3 ceramic
tubes were fabricated by a microscope equipped with a CCD whose scaleplate has been …

Novel principle of contactless gauge block calibration

Z Buchta, Š Řeřucha, B Mikel, M Čížek, J Lazar, O Číp - Sensors, 2012 - mdpi.com
In this paper, a novel principle of contactless gauge block calibration is presented. The
principle of contactless gauge block calibration combines low-coherence interferometry and …

Absolute measurement of gauge block without wringing using tandem low-coherence interferometry

A Winarno, S Takahashi, A Hirai… - Measurement …, 2012 - iopscience.iop.org
A novel method of gauge block measurement without wringing onto a glass platen is
proposed. By using tandem low-coherence interferometry to perform remote measurements …

System for automatic gauge block length measurement optimized for secondary length metrology

Z Buchta, M Šarbort, M Čížek, V Hucl, Š Řeřucha… - Precision …, 2017 - Elsevier
This paper presents a contactless system for automatic gauge blocks calibration based on
combination of laser interferometry and low-coherence interferometry. In the presented …

Linking the optical and the mechanical measurements of dimension by a Newton's rings method

P Balling, Z Ramotowski, R Szumski, A Lassila… - Metrologia, 2019 - iopscience.iop.org
Optical (eg interferometric or laser focus probe) measurement of dimensions must be
corrected to take into account phase change on reflection and the influence of surface …

[PDF][PDF] Linear motion error evaluation of open-loop cnc milling using a laser interferometer

A Winarno, BT Prayoga… - acta mechanica et …, 2022 - intapi.sciendo.com
The usage of computerised numerical control (CNC) machines requires accuracy
verification to ensure the high accuracy of the processed products. This paper introduces an …

Active angular alignment of gauge blocks in double-ended interferometers

Z Buchta, Š Řeřucha, V Hucl, M Čížek, M Šarbort… - Sensors, 2013 - mdpi.com
This paper presents a method implemented in a system for automatic contactless calibration
of gauge blocks designed at ISI ASCR. The system combines low-coherence interferometry …

A New Remote Calibration Method of Length Value Based on Optical Fiber Information Transmission

L Fang, X Sun, H Kong, H Li, M Chen, W Meng - 2023 - preprints.org
The calibration of length is related to the national economy and people's livelihood. The
traditional calibration of length value was sent the uncalibrated instrument to the laboratory …