Instrumented concrete pile tests–part 1: a review of instrumentation and procedures

KN Flynn, BA McCabe - Proceedings of the Institution of Civil …, 2022 - icevirtuallibrary.com
Preliminary pile tests are becoming increasingly routine in piling projects, some of which are
instrumented to help optimise working pile design. However, the execution of a successful …

The Incremental Rigidity Method—More Direct Conversion of Strain to Internal Force in an Instrumented Static Loading Test

VE Komurka, RB Moghaddam - Geo-Congress 2020, 2020 - ascelibrary.org
To convert strain to internal force, it is conventionally assumed that both the foundation's
composite-section elastic modulus, E, and total cross-sectional area, A, are known …

[PDF][PDF] Investigation of shaft friction mechanisms of bored piles through distributed optical fibre strain sensing

H Mohamad, BP Tee, MF Chong… - … Conference on Soil …, 2017 - academia.edu
Recent technological advancement of optical fibre sensing has led new ways in measuring
the performance of geotechnical structures. The distributed sensing, namely Brillouin Optical …

Instrumented concrete pile tests–part 2: strain interpretation

KN Flynn, BA McCabe - Proceedings of the Institution of Civil …, 2022 - icevirtuallibrary.com
The incorporation of strain gauges (traditionally electrical resistance and vibrating wire
gauges but increasingly fibre optic sensors) within concrete piles enables an enhanced …

[PDF][PDF] Pile structural deformation using instrumented test pile with distributed fibre optic sensor

T PIN - 2022 - eprints.utm.my
The distributed fibre optic sensor (DFOS) technology adopted in this study is based on
Brillouin scattering sensing technology known as Brillouin Optical Time Domain Analysis …

Measured end resistance of CFA and drilled displacement piles in San Francisco Area alluvial clay

TC Siegel, TJ Day, B Turner, P Faust - DFI Journal-The Journal of …, 2018 - Taylor & Francis
Continuous Flight Auger (CFA) and drilled displacement (DD) piles in the San Francisco
(California, USA) area are typically designed using a combination of side-and end …

[PDF][PDF] Full-scale load testing and extraction of augered cast-in-place (ACIP) piles in Central Florida

A Marinucci, RB Moghaddam, WM NeSmith - DFI Journal, 2021 - academia.edu
A full-scale field demonstration project consisting of installation, instrumentation, testing, and
extraction of augered cast-in-place (ACIP) piles located in central Florida was undertaken in …

Back analysis of tensile test drilled shafts and barrettes

SS Lin, CH Lai, JC Liao, DEL Ong - Journal of the Chinese Institute …, 2020 - Taylor & Francis
This paper presents a method to interpret the tensile test results for a concrete pile when the
concrete is stressed beyond its tensile limit, which results in anomalies in the strain gage …

Load testing and performance of instrumented ACIP piles in Texas clays

N Massoudi, KR Bell - Geotechnical Frontiers 2017, 2017 - ascelibrary.org
A series of instrumented pile load tests was performed on augered cast in-place piles in an
area northeast of Austin, Texas. The site soils primarily comprised of clays. The load test …

Overburden effect on the axial resistance of instrumented CFA piles

TC Siegel, P Faust - IFCEE 2015, 2015 - ascelibrary.org
Static pile loading tests and high strain dynamic tests were performed to confirm the
foundation design for a major expansion to a hospital on the Stanford University campus in …