Design and experimental assessment of a prestressed lead damper with straight shaft for seismic protection of structures

V Quaglini, C Pettorruso, E Bruschi - Geosciences, 2022 - mdpi.com
This study introduces a new energy dissipation device with a high damping capacity for the
seismic protection of buildings. The device exploits the friction losses between a movable …

Experimental studies on cyclic performance of column base strong axis–aligned asymmetric friction connections

J Borzouie, GA MacRae, JG Chase… - Journal of Structural …, 2016 - ascelibrary.org
This paper describes experimental testing of an asymmetric friction connection (AFC) at the
base of a steel column such as may be used in a moment-frame. Friction/sliding surfaces …

Performance of a damage‐protected beam–column subassembly utilizing external HF2V energy dissipation devices

GW Rodgers, KM Solberg, JG Chase… - Earthquake …, 2008 - Wiley Online Library
Ductile‐jointed connections, which generally require some form of supplementary energy
dissipation to alleviate displacement response, typically employ mild steel energy …

High-force-to-volume seismic dissipators embedded in a jointed precast concrete frame

GW Rodgers, KM Solberg, JB Mander… - Journal of Structural …, 2012 - ascelibrary.org
An experimental and computational study of an 80-percent scale precast concrete 3D beam-
column joint subassembly designed with high force-to-volume (HF2V) dampers and damage …

[HTML][HTML] 装配铅挤压阻尼器的摇摆-自复位双柱墩抗震性能及设计方法

石岩, 钟正午, 秦洪果, 韩建平, 孙治国, 王军文 - 工程力学, 2021 - pubs.cstam.org.cn
为发展具有损伤可控和自复位性能桥梁双柱墩, 选取铅挤压阻尼器(lead-extrusion dampers,
LEDs) 为可更换耗能装置, 并通过预应力筋提供自恢复力, 组成摇摆-自复位(rocking self …

Damage avoidance design steel beam-column moment connection using high-force-to-volume dissipators

TJ Mander, GW Rodgers, JG Chase… - Journal of structural …, 2009 - ascelibrary.org
Existing welded steel moment frames are designed to tolerate substantial yielding and
plastic rotation under earthquake loads. This sacrificial design approach can lead to …

Experimental studies on cyclic performance of column base weak axis aligned asymmetric friction connection

J Borzouie, GA MacRae, JG Chase… - … of Constructional Steel …, 2015 - Elsevier
Applied cyclic imposed displacement tests are conducted on a column base weak axis
aligned asymmetric friction connection (i) in-plane, about the strong axis,(ii) out-of-plane …

State-of-the-art review for lead extrusion dampers: development, improvement, characteristics, application areas, and research needs

F Çalım, A Güllü, C Soydan, E Yüksel - Structures, 2023 - Elsevier
This paper presents a comprehensive state-of-the-art review of the research on the design of
lead extrusion dampers (LED) and their application in the structures. Among the passive …

Theoretical study of the flow in a fluid damper containing high viscosity silicone oil: Effects of shear-thinning and viscoelasticity

A Syrakos, Y Dimakopoulos, J Tsamopoulos - Physics of Fluids, 2018 - pubs.aip.org
The flow inside a fluid damper where a piston reciprocates sinusoidally inside an outer
casing containing high-viscosity silicone oil is simulated using a finite volume method, at …

Beyond ductility: parametric testing of a jointed rocking beam-column connection designed for damage avoidance

GW Rodgers, JB Mander, JG Chase… - Journal of Structural …, 2016 - ascelibrary.org
Despite their good performance in terms of their design objectives, many modern code-
prescriptive buildings built in Christchurch, New Zealand, had to be razed after the 2010 …