Real‐time control of shunt active power filter under distorted grid voltage and unbalanced load condition using self‐tuning filter

S Biricik, S Redif, ÖC Özerdem… - IET Power …, 2014 - Wiley Online Library
In this paper, an alternative control method is proposed to improve the harmonic
suppression efficiency of the active power filter in a distorted and an unbalanced power …

Adaptive notch filter solution under unbalanced and/or distorted point of common coupling voltage for three‐phase four‐wire shunt active power filter with sinusoidal …

ND Dinh, ND Tuyen, G Fujita… - IET Generation …, 2015 - Wiley Online Library
In this study, the three‐phase four‐wire shunt active power filter (ShAPF) dealing with non‐
ideal point of common coupling (PCC) voltages will be presented. The instantaneous power …

Improved harmonic suppression efficiency of single-phase APFs in distorted distribution systems

S Biricik, S Redif, SK Khadem… - International Journal of …, 2016 - Taylor & Francis
In this study, a control method is proposed to improve the harmonic suppression efficiency of
the single-phase active power filter in a distorted power system to suppress current …

Control of the shunt active power filter under non-ideal grid voltage and unbalanced load conditions

S Biricik, S Redif, OC Ozerdem… - 2013 48th International …, 2013 - ieeexplore.ieee.org
In this study a new method is proposed in order to improve the harmonic suppression
efficiency of Active Power Filter for the problems caused by the distorted and unbalanced …

Control of the single phase parallel active filter under weak grid voltages

S Biricik, S Redif, SK Khadem… - 2014 IEEE 5th …, 2014 - ieeexplore.ieee.org
In this study, a control method is proposed to improve the harmonic suppression efficiency of
the single phase active power filter in a distorted power system environment. Here, we …

Notch adaptive filter solution under unbalanced and/or distorted PCC voltage for 3-phase 3-wire shunt active power filter

ND Tuyen, G Fujita, MNB Muhtazaruddin - Electrical Engineering, 2016 - Springer
In this paper, the 3-phase 3-wire Shunt Active Power Filter (ShAPF) dealing with non-ideal
Point of Common Coupling (PCC) voltages will be presented. The instantaneous power …

Etude et Conception d'un Filtre Actif Parallèle Triphasé à Quatre Fils en vue de sa Commande par des Méthodes d'Intelligence Artificielle

T Mahni - 2017 - thesis.univ-biskra.dz
: Les convertisseurs de puissance sont de plus en plus utilisés grâce aux avantages
énormes qu'ils offrent. Cependant ces convertisseurs polluent les réseaux électriques en …

[PDF][PDF] CHEBABHI Ali

PM Ahmed, PF Mohammed-Karim, PM Abdelkader… - researchgate.net
In recent years, the use of static converters is growing rapidly. These converters absorb non-
sinusoidal currents to the network. They behave as generators of harmonic currents, causing …