Calculation of x‐ray spectra emerging from an x‐ray tube. Part II. X‐ray production and filtration in x‐ray targets

GG Poludniowski - Medical physics, 2007 - Wiley Online Library
A new approach to the calculation of the x‐ray spectrum emerging from an x‐ray tube is
proposed. Theoretical results for the bremsstrahlung cross section appearing in the literature …

Calculated and measured brachytherapy dosimetry parameters in water for the Xoft Axxent X‐Ray Source: An electronic brachytherapy source a

MJ Rivard, SD Davis, LA DeWerd, TW Rusch… - Medical …, 2006 - Wiley Online Library
A new x‐ray source, the model S700 Axxent™ X‐Ray Source (Source), has been developed
by Xoft Inc. for electronic brachytherapy. Unlike brachytherapy sources containing …

Current status and new horizons in Monte Carlo simulation of X-ray CT scanners

H Zaidi, MR Ay - Medical & biological engineering & computing, 2007 - Springer
With the advent of powerful computers and parallel processing including Grid technology,
the use of Monte Carlo (MC) techniques for radiation transport simulation has become the …

A method to generate equivalent energy spectra and filtration models based on measurement for multidetector CT Monte Carlo dosimetry simulations

AC Turner, D Zhang, HJ Kim, JJ DeMarco… - Medical …, 2009 - Wiley Online Library
The purpose of this study was to present a method for generating x‐ray source models for
performing Monte Carlo (MC) radiation dosimetry simulations of multidetector row CT …

Efficient x‐ray tube simulations

E Mainegra‐Hing, I Kawrakow - Medical physics, 2006 - Wiley Online Library
This article describes an efficiency study of directional bremsstrahlung splitting (DBS) for x‐
ray tube modeling. DBS is shown to be up to five or six orders of magnitude more efficient at …

Development and validation of MCNP4C-based Monte Carlo simulator for fan-and cone-beam x-ray CT

MR Ay, H Zaidi - Physics in Medicine & Biology, 2005 - iopscience.iop.org
An x-ray computed tomography (CT) simulator based on the Monte Carlo N-particle
radiation transport computer code (MCNP4C) was developed for simulation of both fan-and …

Towards subpercentage uncertainty proton stopping‐power mapping via dual‐energy CT: Direct experimental validation and uncertainty analysis of a statistical …

M Medrano, R Liu, T Zhao, T Webb, DG Politte… - Medical …, 2022 - Wiley Online Library
Purpose To assess the potential of a joint dual‐energy computerized tomography (CT)
reconstruction process (statistical image reconstruction method built on a basis vector model …

A practical reconstruction method for dual energy computed tomography

G Zhang, J Cheng, L Zhang, Z Chen… - Journal of X-ray …, 2008 - content.iospress.com
Quantitative imaging based on dual energy computed tomography (DECT) is useful in both
medical and industrial areas. However, the dependence of the attenuation coefficient on X …

Assessment of PCXMC for patients with different body size in chest and abdominal x ray examinations: a Monte Carlo simulation study

D Borrego, EM Lowe, CM Kitahara… - Physics in Medicine & …, 2018 - iopscience.iop.org
A PC Program for x ray Monte Carlo (PCXMC) has been used to calculate organ doses in
patient dosimetry and for the exposure assessment in epidemiological studies of radiogenic …

[HTML][HTML] Evaluation of x-ray beam quality based on measurements and estimations using SpekCalc and IPEM78 models

SC Chen, WL Jong, AZ Harun - The Malaysian journal of medical …, 2012 - ncbi.nlm.nih.gov
Background: Different computational methods have been used for the prediction of X-ray
spectra and beam quality in diagnostic radiology. The purpose of this study was to compare …