Femoral stem cementation in hip arthroplasty: the know-how of a “lost” art

AK Emara, M Ng, VE Krebs, M Bloomfield… - Current Reviews in …, 2021 - Springer
Abstract Purpose of Review To describe the (1) indications,(2) preoperative precautions,
and (3) stepwise technical details of modern femoral stem cemented fixation. Recent …

Common Factors in Shoulder and Hip Arthroplasty Implant Failures: A Historical Review

R Andrews, JG Layuno-Matos, MA Frankle - Journal of Clinical Medicine, 2024 - mdpi.com
In this era of subspecialty care in orthopedics, iterations of implant design can occur in a silo
which then precludes gaining knowledge from failures of implant design that may have …

The importance of adequate stem anteversion for rotational stability in cemented total hip replacement: a radiostereometric study with ten-year follow-up

S Kiernan, KL Hermann, P Wagner… - The bone & joint …, 2013 - boneandjoint.org.uk
Progressive retroversion of a cemented stem is predictive of early loosening and failure. We
assessed the relationship between direct post-operative stem anteversion, measured with …

Reduced stress shielding with limited micromotions using a carbon fibre composite biomimetic hip stem: a finite element model

C Caouette, LH Yahia… - Proceedings of the …, 2011 - journals.sagepub.com
Total hip arthroplasty (THA) enjoys excellent rates of success in older patients, but younger
patients are still at risk of aseptic loosening and bone resorption from stress shielding. One …

(ii) Biomechanics of implant fixation

B Pal, PK Puthumanapully, AA Amis - Orthopaedics and Trauma, 2013 - Elsevier
In joint replacement, stability of the implant is provided by a combination of the techniques
adopted to fix the implant to the surrounding bone and the geometric features of the implant …

Primary total elbow arthroplasty

A Badre, GJW King - Journal of Clinical Orthopaedics and Trauma, 2021 - Elsevier
There have been significant improvements in surgical techniques and implant designs of
elbow arthroplasty over the last five decades. These advances have resulted in improved …

Characteristic loosening of the distally straight cylindrical femoral stem

G Kimura, E Onishi, K Kawanabe, S Kazutaka… - Journal of Orthopaedic …, 2014 - Springer
Background The cemented femoral stem with a distally straight cylindrical shape was
designed to fill the distal femoral canal to facilitate higher cement pressurization and …

Total Elbow Arthroplasty: Design Considerations

SA Müller, GJW King, JA Johnson - Arthroplasty of the Upper Extremity: A …, 2021 - Springer
Total elbow arthroplasty (TEA) designs can be either unlinked or linked semi-constrained
with a “sloppy hinge.” Unlinked TEA requires an intact or replaced radial head, good bone …

Torsional Stability of a Polished, Collarless, Tapered Total Replacement Hip Joint Stem under Vertical Load: An In Vitro Investigation

A Thomson, AJC Lee - … , Part H: Journal of Engineering in …, 2011 - journals.sagepub.com
The torsional stability of a polished, collarless, tapered total replacement hip joint stem has
been investigated. It was believed that such a stem would show increasing torsional stability …

Distal stem features improve the torsional resistance of long-stem cemented revision hip stems: An in vitro biomechanical study

TP Holsgrove, TG Petheram… - Proceedings of the …, 2013 - journals.sagepub.com
When proximal bone stock is compromised at revision hip arthroplasty, distal fixation is often
relied upon for stability of the femoral component. In such circumstances, torsional forces …