[HTML][HTML] Analytical solution of serial ferroresonance triggered by circuit breaker operation in solidly grounded power grids

B Wang, C Zhang, Y Xia, F Zhang - … Journal of Electrical Power & Energy …, 2023 - Elsevier
Ferroresonance can be induced by Circuit Breaker (CB) switching operations in neutral
point solidly grounded power grids with matching parameters. No complete time domain …

Analysis and simulation of ferroresonance in power transformers using simulink

RP Pineda, R Rodrigues… - IEEE Latin America …, 2018 - ieeexplore.ieee.org
This paper presents a study using Simulink to investigate the response of the voltage
transformers to the phenomenon of ferroresonance. In analyzing the behavior of this …

Extraction of transformer saturation curve from ferroresonance measurements based on Nelder− Mead optimization method

V Milardić, A Tokić, I Uglešić, A Xemard - Electric Power Systems Research, 2023 - Elsevier
An accurate representation of the transformer saturation curve is essential for calculations of
low frequency transients (inrush current, ferroresonance, load rejection) and steady states …

Dual function ferroresonance and fault current limiter based on DC reactor

H Radmanesh, A Heidary, SH Fathi… - IET Generation …, 2016 - Wiley Online Library
This study presents a novel DC reactor‐based ferroresonance and fault current limiter
(DRFFCL) for stabilising ferroresonance oscillations of potential transformer (PT) in 33 kV …

Compound ferroresonance overvoltage and fault current limiter for power system protection

A Heidary, H Radmanesh, A Bakhshi… - IET Energy Systems …, 2020 - Wiley Online Library
Power systems are subjected to various types of faults as well as ferroresonance
overvoltages. These results in the interruption of the normal operation of the power grid …

Distribution network protection using smart dual functional series resonance-based fault current and ferroresonance overvoltage limiter

H Radmanesh - IEEE Transactions on Smart Grid, 2016 - ieeexplore.ieee.org
This paper proposes a smart dual function series resonance ferroresonance overvoltage
and fault current limiter (SRFFCL) for distribution networks. The studied network has …

[PDF][PDF] تحلیل نیروهای الکترومغناطیسی ترانسفورماتور تحت شرایط فرورزونانس در اثر اتصال‌کوتاه سه فاز متوالی با استفاده از روش المان محدود

علی احمدپور, سیدجلال سیدشنوا, سیدجلال… - روش‌های هوشمند در صنعت …, 2020‎ - journals.iau.ir
In this paper, Finite Element Method (FEM) is used to study the ferroresonance phenomenon
from the perspective of the electromagnetic forces introduced on the transformer windings. In …

Determination of single-phase transformer saturation characteristic by using Nelder–Mead optimization method

A Tokić, M Kasumović, M Pejić, V Milardić… - Electrical …, 2021 - Springer
Correctly modelling the nonlinear saturation characteristics of the transformer iron core is of
great importance in steady-state calculations (harmonics and power quality) and …

Impact of the eddy current in the lamination on ferroresonance stability at critical points

A Djebli, F Aboura, L Roubache, O Touhami - International Journal of …, 2019 - Elsevier
The susceptibility of ferroresonance to the eddy current in the iron core is presented in this
paper. The stability of ferroresonance modes is investigated regarding to the eddy current in …

An efficient method for investigating the ferroresonance of single-phase iron core devices

E Cazacu, V Ioniţă, L Petrescu - 2017 10th International …, 2017 - ieeexplore.ieee.org
The paper presents a fast and efficient method for determining the solutions of the
ferroresonant circuits generated at the switching of different single-phase low-voltage iron …