MR fingerprinting for rapid quantification of myocardial T1, T2, and proton spin density

JI Hamilton, Y Jiang, Y Chen, D Ma… - Magnetic resonance …, 2017 - Wiley Online Library
Purpose To introduce a two‐dimensional MR fingerprinting (MRF) technique for
quantification of T1, T2, and M0 in myocardium. Methods An electrocardiograph‐triggered …

[HTML][HTML] Cardiovascular magnetic resonance native T2 and T2* quantitative values for cardiomyopathies and heart transplantations: a systematic review and meta …

GJH Snel, M van den Boomen, LM Hernandez… - Journal of …, 2020 - Elsevier
Background The clinical application of cardiovascular magnetic resonance (CMR) T 2 and T
2* mapping is currently limited as ranges for healthy and cardiac diseases are poorly …

Troponin-positive chest pain with unobstructed coronary arteries: incremental diagnostic value of cardiovascular magnetic resonance imaging

B Pathik, B Raman, NH Mohd Amin… - European Heart …, 2016 - academic.oup.com
Aims Troponin-positive chest pain patients with unobstructed coronaries represent a clinical
dilemma. Cardiovascular magnetic resonance (CMR) imaging has an increasingly …

Role of inflammation and evidence for the use of colchicine in patients with acute coronary syndrome

JF Bulnes, L González, L Velásquez… - Frontiers in …, 2024 - frontiersin.org
Acute Coronary Syndrome (ACS) significantly contributes to cardiovascular death
worldwide. ACS may arise from the disruption of an atherosclerotic plaque, ultimately …

A self-supervised deep learning reconstruction for shortening the breathhold and acquisition window in cardiac magnetic resonance fingerprinting

JI Hamilton - Frontiers in Cardiovascular Medicine, 2022 - frontiersin.org
The aim of this study is to shorten the breathhold and diastolic acquisition window in cardiac
magnetic resonance fingerprinting (MRF) for simultaneous T1, T2, and proton spin density …

[HTML][HTML] Free-running cardiac magnetic resonance fingerprinting: Joint T1/T2 map and Cine imaging

O Jaubert, G Cruz, A Bustin, T Schneider… - Magnetic resonance …, 2020 - Elsevier
Purpose To develop and evaluate a novel non-ECG triggered 2D magnetic resonance
fingerprinting (MRF) sequence allowing for simultaneous myocardial T 1 and T 2 mapping …

Simultaneous multislice cardiac magnetic resonance fingerprinting using low rank reconstruction

JI Hamilton, Y Jiang, D Ma, Y Chen, WC Lo… - NMR in …, 2019 - Wiley Online Library
This study introduces a technique for simultaneous multislice (SMS) cardiac magnetic
resonance fingerprinting (cMRF), which improves the slice coverage when quantifying …

Deep image prior cine MR fingerprinting with B1+ spin history correction

JI Hamilton, GL da Cruz, I Rashid… - Magnetic …, 2024 - Wiley Online Library
Purpose To develop a deep image prior (DIP) reconstruction for B1+‐corrected 2D cine MR
fingerprinting (MRF). Methods The proposed method combines low‐rank (LR) modeling with …

Simultaneous multi-slice cardiac MR multitasking for motion-resolved, non-ECG, free-breathing T1–T2 mapping

X Mao, HL Lee, Z Hu, T Cao, F Han, S Ma… - Frontiers in …, 2022 - frontiersin.org
The aim of this study is to simultaneously quantify T1/T2 across three slices of the left-
ventricular myocardium without breath-holds or ECG monitoring, all within a 3 min scan …

Improved quantitative myocardial T2 mapping: Impact of the fitting model

M Akçakaya, TA Basha, S Weingärtner… - Magnetic resonance …, 2015 - Wiley Online Library
Purpose To develop an improved T2 prepared (T2prep) balanced steady‐state free‐
precession (bSSFP) sequence and signal relaxation curve fitting method for myocardial T2 …