Bimodular femoral stems in primary total hip arthroplasty

J Zajc, SK Fokter - Expert Review of Medical Devices, 2023 - Taylor & Francis
Introduction This review critically examines the efficacy of dual-modular stems in primary
total hip arthroplasty. Given the variability and non-comparability of certain femoral stem …

Navigation and robotics in total hip arthroplasty

AS Wasterlain, JA Buza III, SC Thakkar… - JBJS …, 2017 - journals.lww.com
Navigation and Robotics in Total Hip Arthroplasty : JBJS Reviews Navigation and Robotics in
Total Hip Arthroplasty : JBJS Reviews JBJS Journal Case Connector Reviews JBJS.org …

Exchangeable femoral neck (dual-modular) THA prostheses have poorer survivorship than other designs: a nationwide cohort of 324,108 patients

S Colas, A Allalou, A Poichotte, P Piriou… - … and Related Research®, 2017 - Springer
Background Exchangeable neck stems, defined as those with a dual taper (that is, a
modular junction between the femoral head and the femoral neck and an additional junction …

Dual modular titanium alloy femoral stem failure mechanisms and suggested clinical approaches

J Zajc, A Moličnik, SK Fokter - Materials, 2021 - mdpi.com
Titanium (Ti) alloys have been proven to be one of the most suitable materials for
orthopaedic implants. Dual modular stems have been introduced to primary total hip …

Effect of simulated inflammatory conditions and potential on dissolution and surface oxide of CoCrMo alloy: In situ electrochemical atomic force microscopy study

Y Liu, JL Gilbert - Electrochimica Acta, 2018 - Elsevier
Inflammation may develop in association with implantation of hip replacements and the
inflammatory state of the local body fluids may affect the corrosion of metallic biomaterials …

The chemical form of metal species released from corroded taper junctions of hip implants: synchrotron analysis of patient tissue

A Di Laura, PD Quinn, VC Panagiotopoulou… - Scientific reports, 2017 - nature.com
The mechanisms of metal release from the articulation at the head cup bearing and the
tapered junctions of orthopaedic hip implants are known to differ and the debris generated …

Early outcomes of revision surgery for taper corrosion of dual taper total hip arthroplasty in 187 patients

D Dimitriou, MHL Liow, TY Tsai, WA Leone, G Li… - The Journal of …, 2016 - Elsevier
Background Modular dual taper femoral neck designs have been associated with taper
corrosion requiring revision surgery. However, outcomes after revision dual taper total hip …

[HTML][HTML] Adverse tissue reaction to corrosion at the neck-stem junction after modular primary total hip arthroplasty

G Gkagkalis, P Mettraux, P Omoumi, S Mischler… - … & Traumatology: Surgery …, 2015 - Elsevier
Complications related to the neck-stem junction of modular stems used for total hip
arthroplasty (THA) are generating increasing concern. A 74-year-old male had increasing …

Cementless modular neck stems: are they a safe option in primary total hip arthroplasty?

JM Pelayo-de-Tomás, JL Rodrigo-Pérez… - European Journal of …, 2018 - Springer
Purpose The objective was to assess aseptic complications and functional outcome using a
primary total hip arthroplasty with modular neck. Methods Prospective cohort of 317 …

Retrieval analysis of neck-stem coupling in modular hip prostheses

SL Su, CN Koch, TM Nguyen, JC Burket… - The Journal of …, 2017 - Elsevier
Background Dual-taper modular stems have suffered from high revision rates caused by
adverse local tissue reactions secondary to fretting and corrosion. We compared the fretting …