Review of laser-driven ion sources and their applications

H Daido, M Nishiuchi… - Reports on progress in …, 2012 - iopscience.iop.org
For many years, laser-driven ion acceleration, mainly proton acceleration, has been
proposed and a number of proof-of-principle experiments have been carried out with lasers …

The Soreq applied research accelerator facility (SARAF): overview, research programs and future plans

I Mardor, O Aviv, M Avrigeanu, D Berkovits… - The European Physical …, 2018 - Springer
The Soreq Applied Research Accelerator Facility (SARAF) is under construction in the Soreq
Nuclear Research Center at Yavne, Israel. When completed at the beginning of the next …

Towards a more complete and accurate experimental nuclear reaction data library (EXFOR): international collaboration between nuclear reaction data centres (NRDC …

N Otuka, E Dupont, V Semkova, B Pritychenko… - Nuclear Data …, 2014 - Elsevier
Abstract The International Network of Nuclear Reaction Data Centres (NRDC) coordinated
by the IAEA Nuclear Data Section (NDS) successfully collaborates in the maintenance and …

Energy levels of light nuclei A= 11

JH Kelley, E Kwan, JE Purcell, CG Sheu, HR Weller - Nuclear Physics A, 2012 - Elsevier
A review of evidence on the properties of the A= 11 nuclei, with emphasis on material
leading to information about the structure of the A= 11 systems.

Recommended nuclear data for medical radioisotope production: diagnostic gamma emitters

FT Tárkányi, AV Ignatyuk, A Hermanne… - … of Radioanalytical and …, 2019 - Springer
An extensive series of evaluations have been performed as part of an IAEA coordinated
research project to study a set of nuclear reactions that produce the diagnostic gamma-ray …

Radionuclide candidates for β+ γ coincidence PET: an overview

M Sitarz, JP Cussonneau, T Matulewicz… - Applied Radiation and …, 2020 - Elsevier
Following the advancement of the Positron Emission Tomography (PET), a novel technique
emerged which takes advantage of the gamma quanta emitted, in some cases, after the β+ …

The reliability of proton-nuclear interaction cross-section data to predict proton-induced PET images in proton therapy

S Espana, X Zhu, J Daartz, G El Fakhri… - Physics in Medicine …, 2011 - iopscience.iop.org
In vivo PET range verification relies on the comparison of measured and simulated activity
distributions. The accuracy of the simulated distribution depends on the accuracy of the …

Investigation of proton beam-driven fusion reactions generated by an ultra-short petawatt-scale laser pulse

MS Schollmeier, V Shirvanyan, C Capper… - Laser and Particle …, 2022 - cambridge.org
We present results from a pitcher-catcher experiment utilizing a proton beam generated with
nanostructured targets at a petawatt-class, short-pulse laser facility to induce proton-boron …

Validation and upgrading of the recommended cross-section data of charged particle reactions: Gamma emitter radioisotopes

S Takacs, F Tárkányi, A Hermanne - … in Physics Research Section B: Beam …, 2005 - Elsevier
An upgrade and validation test of the recommended cross-section database for production
of gamma emitter radioisotopes by charged particle induced reactions, published by the …

Upgrade of IAEA recommended data of selected nuclear reactions for production of PET and SPECT isotopes

A Hermanne, FT Tarkanyi, AV Ignatyuk, S Takács… - Nuclear Data …, 2021 - Elsevier
An IAEA research project was dedicated to the compilation, evaluation and recommendation
of cross-section data for the accelerator production of 11 C, 13 N, 15 O, 18 F, 64 Cu, and 124 …