From simultaneous to synergistic MR‐PET brain imaging: A review of hybrid MR‐PET imaging methodologies

Z Chen, SD Jamadar, S Li, F Sforazzini… - Human brain …, 2018 - Wiley Online Library
Abstract Simultaneous Magnetic Resonance Imaging (MRI) and Positron Emission
Tomography (PET) scanning is a recent major development in biomedical imaging. The full …

Development of clinical simultaneous SPECT/MRI

BF Hutton, M Occhipinti, A Kuehne… - The British journal of …, 2018 - academic.oup.com
There is increasing clinical use of combined positron emission tomography and MRI, but to
date there has been no clinical system developed capable of simultaneous single-photon …

Conditional generative adversarial networks aided motion correction of dynamic 18F-FDG PET brain studies

LKS Sundar, D Iommi, O Muzik… - Journal of Nuclear …, 2021 - Soc Nuclear Med
This work set out to develop a motion-correction approach aided by conditional generative
adversarial network (cGAN) methodology that allows reliable, data-driven determination of …

PET/MRI hybrid systems

JG Mannheim, AM Schmid, J Schwenck… - Seminars in nuclear …, 2018 - Elsevier
Over the last decade, the combination of PET and MRI in one system has proven to be
highly successful in basic preclinical research, as well as in clinical research. Nowadays …

Towards quantitative [18F] FDG-PET/MRI of the brain: automated MR-driven calculation of an image-derived input function for the non-invasive determination of …

LKS Sundar, O Muzik, L Rischka… - Journal of Cerebral …, 2019 - journals.sagepub.com
Absolute quantification of PET brain imaging requires the measurement of an arterial input
function (AIF), typically obtained invasively via an arterial cannulation. We present an …

Synergistic motion compensation strategies for positron emission tomography when acquired simultaneously with magnetic resonance imaging

I Polycarpou, G Soultanidis… - … Transactions of the …, 2021 - royalsocietypublishing.org
Subject motion in positron emission tomography (PET) is a key factor that degrades image
resolution and quality, limiting its potential capabilities. Correcting for it is complicated due to …

Markerless motion tracking and correction for PET, MRI, and simultaneous PET/MRI

JM Slipsager, AH Ellegaard, SL Glimberg, RR Paulsen… - Plos one, 2019 - journals.plos.org
Objective We demonstrate and evaluate the first markerless motion tracker compatible with
PET, MRI, and simultaneous PET/MRI systems for motion correction (MC) of brain imaging …

Rigid motion correction for brain PET/MR imaging using optical tracking

MG Spangler-Bickell, MM Khalighi… - IEEE transactions on …, 2018 - ieeexplore.ieee.org
A significant challenge during high-resolution PET brain imaging on PET/MR scanners is
patient head motion. This challenge is particularly significant for clinical patient populations …

MRI-driven PET image optimization for neurological applications

Y Zhu, X Zhu - Frontiers in Neuroscience, 2019 - frontiersin.org
Positron emission tomography (PET) and magnetic resonance imaging (MRI) are
established imaging modalities for the study of neurological disorders, such as epilepsy …

Technical and instrumentational foundations of PET/MRI

I Rausch, HH Quick, J Cal-Gonzalez, B Sattler… - European Journal of …, 2017 - Elsevier
This paper highlights the origins of combined positron emission tomography (PET) and
magnetic resonance imaging (MRI) whole-body systems that were first introduced for …