Numerical study on behavior of bolted shear connector used in composite cold-formed steel beams

M Hosseinpour, M Zeynalian, M Daei, A Ataei - Thin-Walled Structures, 2022 - Elsevier
The use of concrete slab in cold-formed steel (CFS) beams can not only increase the
ultimate resistance, but also can prevent their lateral buckling. Since the formation of …

Push-out tests on bolted shear connectors in composite cold-formed steel beams

M Hosseinpour, M Zeynalian, A Ataei, M Daei - Thin-Walled Structures, 2021 - Elsevier
Composite beams comprised of steel sections and concrete slabs, are one of the most
widely used beams due to their advantages such as improving stiffness and strength …

Neural networks-based formulation for predicting ultimate strength of bolted shear connectors in composite cold-formed steel beams

M Hosseinpour, M Daei, M Zeynalian, A Ataei - Engineering Applications of …, 2023 - Elsevier
In recent years, the use of artificial intelligence-based methods in engineering problems has
been expanded. In the current study, the method of artificial neural networks (ANN) has …

Mechanical performance of GFRP-profiled steel sheeting composite sandwich beams in four-point bending

F Zhang, W Liu, Z Ling, H Fang, D Jin - Composite Structures, 2018 - Elsevier
This study proposed a novel GFRP-profiled steel sheeting composite sandwich beam
(GPSS beam) composed of glass fiber reinforced polymer (GFRP) skins, a lightweight …

Numerical modeling on thin-walled cold-formed steel clip angles subjected to pull-out failures

M Obeydi, M Daei, M Zeynalian, M Abbasi - Thin-Walled Structures, 2021 - Elsevier
Pull-out failures are one of the common failures in load bearing cold-formed steel clip angles
causing catastrophic damages, where plate and screw fastener are dislocated. Thus, a …

An experimental study on structural performance of U-shaped shear connector in composite cold-formed steel floor joists

M Hosseinpour, M Zeynalian, A Ataei, M Daei - Engineering Structures, 2021 - Elsevier
Since few studies have focused on the shear connectors in the composite cold-formed steel
beams so far, this paper studies the behavior of the U-shaped shear connectors which can …

Seismic response of cold formed steel frames sheathed by fiber cement boards

M Zeynalian, AZ Shahrasbi, HT Riahi - International Journal of Civil …, 2018 - Springer
In this paper, the seismic performance of cold formed steel shear walls sheathed by fiber
cement boards (FCB) is investigated. Of particular interest is the seismic response …

Strength and stiffness of floor trusses fabricated from cold-formed steel lipped channels

Ç Dizdar, E Baran, C Topkaya - Engineering Structures, 2019 - Elsevier
This paper reports findings of an experimental study on floor trusses fabricated from cold-
formed steel lipped channel sections. In design, the members of these trusses are generally …

Experimental research on circular concrete filled stainless steel tubular truss

W Zhou, Y Chen, K Wang, S Han, FP Galarza - Thin-Walled Structures, 2017 - Elsevier
The flexural behaviour of circular concrete filled stainless steel tubular trusses is presented
in this paper. A total of four specimens were tested, including three circular concrete filled …

A numerical study on a novel demountable cold-formed steel composite beam with profiled steel sheeting

A Karimipanah, M Zeynalian, A Ataei - Thin-Walled Structures, 2024 - Elsevier
Cold-formed steel composite beams are known for their unique advantages, like being
lightweight and ease of installation. The use of profiled steel sheeting in cold-formed …