Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques

ID Gelalis, NK Paschos, EE Pakos, AN Politis… - European spine …, 2012 - Springer
Introduction With the advances and improvement of computer-assisted surgery devices,
computer-guided pedicle screws insertion has been applied to the lumbar, thoracic and …

The accuracy of pedicle screw placement using intraoperative image guidance systems: a systematic review

A Mason, R Paulsen, JM Babuska, S Rajpal… - … of Neurosurgery: Spine, 2014 - thejns.org
Object Several retrospective studies have demonstrated higher accuracy rates and
increased safety for navigated pedicle screw placement than for free-hand techniques; …

Clinical acceptance and accuracy assessment of spinal implants guided with SpineAssist surgical robot: retrospective study

DP Devito, L Kaplan, R Dietl, M Pfeiffer, D Horne… - Spine, 2010 - journals.lww.com
Study Design. Retrospective, multicenter study of robotically-guided spinal implant
insertions. Clinical acceptance of the implants was assessed by intraoperative radiograph …

Perioperative course and accuracy of screw positioning in conventional, open robotic-guided and percutaneous robotic-guided, pedicle screw placement

SR Kantelhardt, R Martinez, S Baerwinkel… - European Spine …, 2011 - Springer
Robotic-guided and percutaneous pedicle screw placement are emerging technologies. We
here report a retrospective cohort analysis comparing conventional open to open robotic …

Spinal robotics: current applications and future perspectives

F Roser, M Tatagiba, G Maier - Neurosurgery, 2013 - journals.lww.com
Even though robotic technology holds great potential for performing spinal surgery and
advancing neurosurgical techniques, it is of utmost importance to establish its practicality …

[HTML][HTML] The current state of navigation in robotic spine surgery

M Huang, TA Tetreault, A Vaishnav… - Annals of …, 2021 - ncbi.nlm.nih.gov
The advent and widespread adoption of pedicle screw instrumentation prompted the need
for image guidance in spine surgery to improve accuracy and safety. Although the …

Assessment of different screw augmentation techniques and screw designs in osteoporotic spines

S Becker, A Chavanne, R Spitaler, K Kropik… - European Spine …, 2008 - Springer
This is an experimental study on human cadaver spines. The objective of this study is to
compare the pullout forces between three screw augmentation methods and two different …

Feasibility and accuracy of thoracolumbar minimally invasive pedicle screw placement with augmented reality navigation technology

A Elmi-Terander, R Nachabe, H Skulason, K Pedersen… - Spine, 2018 - journals.lww.com
Study Design. Cadaveric laboratory study. Objective. To assess the feasibility and accuracy
of minimally invasive thoracolumbar pedicle screw placement using augmented reality (AR) …

Economic evaluation comparing intraoperative cone beam CT-based navigation and conventional fluoroscopy for the placement of spinal pedicle screws: a patient …

N Dea, CG Fisher, J Batke, J Strelzow, D Mendelsohn… - The Spine Journal, 2016 - Elsevier
Abstract Background Context Pedicle screws are routinely used in contemporary spinal
surgery. Screw misplacement may be asymptomatic but is also correlated with potential …

Retrospective computed tomography scan analysis of percutaneously inserted pedicle screws for posterior transpedicular stabilization of the thoracic and lumbar …

DA Raley, RJ Mobbs - Spine, 2012 - journals.lww.com
Study Design. Retrospective clinical data analysis. Objective. To investigate the
misplacement rate and related clinical complications of percutaneous pedicle screw …