Prompt gamma spectroscopy retrieval algorithm for element and density measurements accelerated by cloud computing

JL Wang, XG Wu, ZF Li, SQ Xie, DQ Hei, ZH Zhao… - Frontiers in …, 2022 - frontiersin.org
Prompt gamma ray in proton therapy is the product of a nuclear reaction between a proton
and a target. The characteristic energies and intensities of prompt gamma lines can be used …

Analytical modeling and Monte Carlo simulations of multi-parallel slit and knife-edge slit prompt gamma cameras

BFB Huisman, E Muñoz, D Dauvergne… - Physics in Medicine …, 2023 - iopscience.iop.org
Purpose. Present and validate an analytical model (AM) to calculate efficiency and spatial
resolution of multi-parallel slit (MPS) and knife-edge slit (KES) cameras in the context of …

[HTML][HTML] Tackling range uncertainty in proton therapy: development and evaluation of a new multi-slit prompt-gamma camera (MSPGC) system

Y Ku, S Choi, J Cho, S Jang, JH Jeong, SH Kim… - Nuclear Engineering …, 2023 - Elsevier
In theory, the sharp dose falloff at the distal end of a proton beam allows for high conformal
dose to the target. However, conformity has not been fully achieved in practice, primarily due …

Design and performance evaluation of a slit‐slat camera for 2D prompt gamma imaging in proton therapy monitoring: A Monte Carlo simulation study

E Malekzadeh, H Rajabi, MA Tajik‐Mansoury… - Medical …, 2023 - Wiley Online Library
Purpose We investigated the design of a prompt gamma camera for real‐time dose delivery
verification and the partial mitigation of range uncertainties. Methods A slit slat (SS) camera …

Design and performance evaluation of a coded aperture imaging system for real-time prompt gamma-ray monitoring during proton therapy

S Sun, Y Liu, X Ouyang - Radiation Physics and Chemistry, 2020 - Elsevier
A new mechanical collimated system capable of 2-dimensional (2D) prompt gamma-ray
imaging is proposed for proton beam range verification and dose monitoring. To achieve …

Treatment verification in particle therapy

C Gianoli, M De Simoni, A Knopf - Imaging in Particle Therapy …, 2024 - iopscience.iop.org
To make the most of the physical and biological potentials of Particle Therapy (PT), it would
be extremely desirable to verify dose deposition in vivo. In this chapter, we describe and …

Developing an Analytical Model for Knife-Edge Slit Collimator Optimization for Prompt Gamma Imaging in Proton Therapy

E Malekzadeh - Frontiers in Biomedical Technologies, 2023 - publish.kne-publishing.com
Purpose: Gamma cameras are one of the most promising technologies for in-vivo range
monitoring in proton therapy. Monte Carlo (MC) simulation is a common calculation-based …

[PDF][PDF] Analytical and Monte-Carlo modeling of multi-parallel slit and knife-edge slit prompt gamma cameras

E Testa, BFB Huisman… - Proc …, 2019 - public-poster-links.s3.amazonaws …
Objectives▶ Development an analytical model (AM) of MPS and KES collimations⇒ main
intrinsic features of each collimator▶ Verification of the AM by means of Monte Carlo (MC) …

Monte Carlo Simulation of Thallium-Bromide Semiconductor Detector for Range Verification of a Carbon Ion Radiotherapy Beam through Prompt Gamma-Ray …

P Dimpfl - 2022 - search.proquest.com
Thallium-Bromide is a semiconductor material which is well suited for photon detection.
Composed of high atomic number elements and a high mass density of 7.56 g/cm3, TlBr has …

[PDF][PDF] Studies of performance and background in a Compton camera for proton therapy treatment monitoring

MB Lloret - roderic.uv.es
In 1895, the discovery of X-rays and by Röntgen resulted in the use of ionizing radiation in
medical and other applications. Besides their use in diagnostic imaging, high-energy …