Numerical simulation of heat dissipation processes in underground power cable system situated in thermal backfill and buried in a multilayered soil

P Ocłoń, P Cisek, M Pilarczyk, D Taler - Energy Conversion and …, 2015 - Elsevier
This paper presents the thermal analysis of the underground transmission line, planned to
be installed in one of the Polish power plants. The computations are performed by using the …

Thermal performance optimization of the underground power cable system by using a modified Jaya algorithm

P Ocłoń, P Cisek, M Rerak, D Taler, RV Rao… - International Journal of …, 2018 - Elsevier
This paper presents a modified Jaya algorithm for optimizing the material costs and electric-
thermal performance of an Underground Power Cable System (UPCS). A High Voltage (HV) …

Numerical simulation of coupled heat, liquid water and water vapor in soils for heat dissipation of underground electrical power cables

E Kroener, A Vallati, M Bittelli - Applied Thermal Engineering, 2014 - Elsevier
The trend towards renewable energy comes along with a more and more decentralized
production of electric energy. As a consequence many countries will have to build hundreds …

The performance analysis of a new thermal backfill material for underground power cable system

P Ocłoń, M Bittelli, P Cisek, E Kroener… - Applied Thermal …, 2016 - Elsevier
Lafarge Gruntar™ material is proposed in this paper as a new thermal backfill component,
and different mass fractions such as 5%, 10%, and 15% are examined. The thermal …

Thermal analysis of underground power cable system

M Rerak, P Ocłoń - Journal of Thermal Science, 2017 - Springer
The paper presents the application of Finite Element Method in thermal analysis of
underground power cable system. The computations were performed for power cables …

[PDF][PDF] 夹具对高压绝缘电缆热学特性影响的有限元分析

吕安强, 李静, 张振鹏, 宋贺, 林晓波 - 电工技术学报, 2022 - dgjsxb.ces-transaction.com
摘要夹具是已敷设高压绝缘电缆线路中的必备组件, 为了获得夹具对缆体热学特性的影响,
以典型220kV 交流单芯交联聚乙烯(XLPE) 绝缘电缆为对象进行电热耦合有限元分析 …

Underground electric cables a correct evaluation of the soil thermal resistance

F Salata, F Nardecchia, A de Lieto Vollaro… - Applied Thermal …, 2015 - Elsevier
Nowadays companies supplying medium/high voltage electric energy, near residential
areas, tend to use underground cables laying. Hence the design engineer is required to …

3-D thermal analysis and contact resistance evaluation of power cable joint

F Yang, P Cheng, H Luo, Y Yang, H Liu… - Applied Thermal …, 2016 - Elsevier
Aiming at the overheating problem of power cable joints, which is mainly caused by great
contact resistance and unqualified installation, a 3-D electromagnetic-thermal model for …

Experimental study of thermal field deriving from an underground electrical power cable buried in non-homogeneous soils

R de Lieto Vollaro, L Fontana, A Vallati - Applied thermal engineering, 2014 - Elsevier
The electrical cables ampacity mainly depends on the cable system operation temperature.
To achieve a better cable utilization and reduce the conservativeness typically employed in …

Improved ampacity of buried HVDC cable with high thermal conductivity LDPE/BN insulation

BX Du, XX Kong, B Cui, J Li - IEEE Transactions on Dielectrics …, 2017 - ieeexplore.ieee.org
Polyethylene is widely used as insulation in power cables with its excellent electrical
properties except its low thermal conductivity. However, insulation-related thermal problems …