[HTML][HTML] Statistical approach for detection of fault and stable and unstable power swings based on signal energy

A Kaffashbashi, Y Damchi - International Journal of Electrical Power & …, 2023 - Elsevier
Distance relays, as the main protection of the transmission lines, are prone to maloperation
during power swings. Therefore, the detection of faults and stable and unstable power …

An overview of power swing detection methods in distance relays and the factors involved

B Taheri, SA Hosseini… - IET Generation …, 2023 - Wiley Online Library
Nowadays, due to the simplicity of operation and proper coordination characteristics,
distance relays are being extensively used in the protection of power transmission lines …

A deep sequence-to-sequence model for power swing blocking of distance protection in power transmission lines

AM Birgani, M Shams, M Jannati… - Engineering Applications of …, 2025 - Elsevier
As the primary protection method for transmission lines, distance relays are prone to
malfunction during power swings. In fact, the inability of distance relays to differentiate …

Improving power swing detection in the presence of doubly-fed induction generator wind farms based on setting adaptation

S Bahari, H Seyedi, K Zare - Electric Power Systems Research, 2023 - Elsevier
This article proposes a new approach to improve the security of transmission line protection
by correctly detecting power swing when large-scale doubly-fed induction generator wind …

Pavement dynamic monitoring data processing based on wavelet decomposition and reconfiguration methods

S Shang, M Liang, H Wang, Y Jiao, Z Liu, C Bi… - Frontiers in …, 2023 - frontiersin.org
Early damage to asphalt pavements generally occurs due to the increasing traffic flow and
the loads of vehicles, coupled with alternating high-and low-temperature cycles, freeze …

A novel sparse approximation-based peak detecting algorithm to differentiate faults from power swings

S Akolkar, HR Jariwala - Electrical Engineering, 2023 - Springer
During a power swing, the distance relay should be blocked, but it should operate reliably
when any fault occurs, even if it is during a power swing. Detecting any type of fault quickly …

Leveraging Smart Meter Technology to Combat Energy Theft and Empower Consumption Monitoring

V Mohanapriya, PR Raaghav, D Ranjan… - 2024 10th …, 2024 - ieeexplore.ieee.org
Monitoring electricity theft is an integral part in reducing energy losses in electrical power
systems. Electricity losses can arise at all levels, starting at generation, followed through …