How the mechanical microenvironment of stem cell growth affects their differentiation: A review

X Zhang, S Zhang, T Wang - Stem cell research & therapy, 2022 - Springer
Stem cell differentiation is of great interest in medical research; however, specifically and
effectively regulating stem cell differentiation is still a challenge. In addition to chemical …

Prevention and repair of orthodontically induced root resorption using ultrasound: a scoping review

MS Adly, AS Adly, R Younes, M El Helou… - Expert Review of …, 2023 - Taylor & Francis
Introduction This review summarizes the available recent literature on different mechanisms
and parameters of pulsed ultrasound (US) that have been used during orthodontic …

[HTML][HTML] Functional non-uniformity of periodontal ligaments tunes mechanobiological stimuli across soft-and hard-tissue interfaces

J Zhong, Y Shibata, C Wu, C Watanabe, J Chen… - Acta Biomaterialia, 2023 - Elsevier
The bone-periodontal ligament-tooth (BPT) complex is a unique mechanosensing soft-/hard-
tissue interface, which governs the most rapid bony homeostasis in the body responding to …

Assessment of the best FEA failure criteria (Part I): Investigation of the biomechanical behavior of PDL in intact and reduced periodontium

RA Moga, SM Buru, CD Olteanu - International Journal of Environmental …, 2022 - mdpi.com
The accuracy of five failure criterions employed in the study of periodontal ligaments (PDL)
during periodontal breakdown under orthodontic movements was assessed. Based on cone …

Assessment of the Maximum Amount of Orthodontic Force for Dental Pulp and Apical Neuro-Vascular Bundle in Intact and Reduced Periodontium on Bicuspids (Part II …

RA Moga, CD Olteanu, M Botez, SM Buru - International journal of …, 2023 - mdpi.com
This study examines 0.6 N–4.8 N as the maximum orthodontic force to be applied to dental
pulp and apical NVB on intact and 1–8 mm reduced periodontal-ligament (PDL), in …

Assessment of the Orthodontic External Resorption in Periodontal Breakdown—A Finite Elements Analysis (Part I)

RA Moga, CD Olteanu, MD Botez, SM Buru - Healthcare, 2023 - mdpi.com
This Finite Elements Analysis (FEA) assessed the accuracy of Tresca failure criteria
(maximum shear stress) for the study of external root resorption. Additionally, the tooth …

Assessment of the Best FEA Failure Criteria (Part II): Investigation of the Biomechanical Behavior of Dental Pulp and Apical-Neuro-Vascular Bundle in Intact and …

RA Moga, SM Buru, CD Olteanu - International Journal of Environmental …, 2022 - mdpi.com
The aim of this study was to biomechanically assess the behavior of apical neuro-vascular
bundles (NVB) and dental pulp employing Tresca, Von Mises, Pressure, S1 and S3 failure …

Orthodontically induced root resorption: A critical analysis of finite element studies' input and output

MG Roscoe, PM Cattaneo, M Dalstra, OM Ugarte… - American Journal of …, 2021 - Elsevier
Introduction Orthodontically induced inflammatory root resorption (OIIRR) constitutes an
undesirable risk connected to orthodontic treatment. Finite element analysis (FEA) is a …

Efficacy of microchips and 3D sensors for orthodontic force measurement: A systematic review of in vitro studies

CM Ardila, DE Arrubla‐Escobar… - Orthodontics & …, 2024 - Wiley Online Library
Objective To evaluate the efficacy of microchips and 3D microsensors in the measurement of
orthodontic forces. Methods Through September 2023, comprehensive searches were …

Investigating the Ability of the Tooth and Surrounding Support Tissues to Absorb and Dissipate Orthodontic Loads during Periodontal Breakdown—Finite Elements …

RA Moga, CD Olteanu, AG Delean - Applied Sciences, 2024 - mdpi.com
Featured Application For an orthodontist practitioner, quantification of the absorption–
dissipation ability of dental tissues is of extreme importance since there is a constant danger …