Power harmonics and interharmonics measurement using recursive group-harmonic power minimizing algorithm

HC Lin - IEEE Transactions on Industrial Electronics, 2011 - ieeexplore.ieee.org
The discrete Fourier transform (DFT) is still a widely used tool for analyzing and measuring
both stationary and transient signals in power system harmonics. However, the …

Dependence of voltage fluctuation severity on clipped sinewave distortion of voltage

P Kuwałek, G Wiczyński - IEEE Transactions on Instrumentation …, 2021 - ieeexplore.ieee.org
The article presents the novel findings on the dependence of voltage fluctuation severity on
voltage distortion caused by power electronic loads. The results indicate the need to modify …

Towards limiting the sensitivity of energy-efficient lighting to voltage fluctuations

I Azcarate, JJ Gutierrez, A Lazkano, P Saiz… - … and Sustainable Energy …, 2016 - Elsevier
In recent years, several countries have adopted measures aimed at improving the efficiency
of energy usage and reducing energy costs. One initiative has been to encourage the use of …

Distributed generation grid-connected converter testing device based on cascaded H-bridge topology

Y Li, Y Wang, R Wang, J Wu, H Zhang… - IEEE Transactions …, 2015 - ieeexplore.ieee.org
This paper presents the configuration, control, and implementation of a testing device to
check the reliability of a high-voltage high-power distributed generation (DG) grid-connected …

Development of a flickermeter to measure non-incandescent lamps flicker

A Hooshyar, EF El-Saadany - IEEE transactions on power …, 2013 - ieeexplore.ieee.org
The flickermeter described in International Electrotechnical Commission (IEC) Standard
61000-4-15 is widely used to quantify the voltage flicker level in practical applications. The …

Interharmonic Power–A New Concept for Power System Oscillation Source Location

W Xu, J Yong, HJ Marquez, C Li - IEEE Transactions on Power …, 2025 - ieeexplore.ieee.org
Power system oscillations are a significant concern for system operators, a problem that has
grown due to the interconnection of inverter-based resources. To address this issue, various …

A method to improve the interharmonic grouping scheme adopted by IEC standard 61000-4-7

J Hui, H Yang, W Xu, Y Liu - IEEE transactions on Power …, 2012 - ieeexplore.ieee.org
The interharmonic group concept adopted by the IEC 61000-4-7 is very useful for
addressing the need to monitor interharmonics in power systems. This paper shows that …

[HTML][HTML] Detection method of interharmonic pairs-caused voltage peak fluctuation flicker

J Wang, J Zhao, H Xiao, C Zuo, Z Chen - Energy Reports, 2022 - Elsevier
Interharmonics of high frequency will cause voltage's peak value fluctuation, which will result
in flicker of fluorescent lamp and LED lamp. To realize accurate evaluation of the flicker, a …

Addressing IEC flickermeter deficiencies by digital filtration inside a sliding window

A Hooshyar, MA Azzouz… - IEEE Transactions on …, 2013 - ieeexplore.ieee.org
Although globally deployed for flicker assessment, the flickermeter presented by
International Electrotechnical Commission (IEC) Standard 61000-4-15 has been proved to …

Fuzzy logic voltage flicker estimation using Kalman filter

HM Al-Hamadi - International Journal of Electrical Power & Energy …, 2012 - Elsevier
Accurate tracking and estimation of the voltage flicker levels is important for effective design
and implementations of voltage mitigation devices. This paper presents tracking and …