Noise-immune cavity-enhanced optical heterodyne molecular spectroscopy: Current status and future potential

A Foltynowicz, FM Schmidt, W Ma, O Axner - Applied Physics B, 2008 - Springer
As a result of a combination of an external cavity and modulation techniques, noise-immune
cavity-enhanced optical heterodyne molecular spectroscopy (NICE-OHMS) is one of the …

On the 12 C 2 H 2 near-infrared spectrum: absolute transition frequencies and an improved spectroscopic network at the kHz accuracy level

A Castrillo, E Fasci, T Furtenbacher… - Physical Chemistry …, 2023 - pubs.rsc.org
Lamb dips of twenty lines in the P, Q, and R branches of the ν1+ ν3+ ν41 vibrational band of
12C2H2, in the spectral window of 7125–7230 cm− 1, have been measured using an …

[PDF][PDF] 腔增强呼吸气体诊断技术概述

管世钰, 曹慧琳, 罗治福, 谭中奇 - Laser & Optoelectronics …, 2022 - researching.cn
摘要基于呼吸气体分析的疾病诊断技术, 属于无损医学诊断研究范畴, 是今后医学诊断的重要
发展方向, 将会在今后无损医学疾病诊断中发挥重要作用, 尤其是在当下新冠疫情肆虐的背景下 …

High-speed multi-pass tunable diode laser absorption spectrometer based on frequency-modulation spectroscopy

C Li, L Shao, H Meng, J Wei, X Qiu, Q He, W Ma… - Optics express, 2018 - opg.optica.org
We report a multi-pass tunable diode laser absorption spectrometer based on the frequency-
modulation spectroscopy (FMS) technique. It has the advantage of high scan speed and is …

Advances in cavity-enhanced methods for high precision molecular spectroscopy and test of fundamental physics

L Gianfrani, SM Hu, W Ubachs - La Rivista del Nuovo Cimento, 2024 - Springer
Cavity-enhanced spectroscopic techniques are highly sensitive laser-based methods for
interrogating the atomic and molecular constituents of any gaseous medium that is confined …

Lamb-dip cavity ring-down spectroscopy of acetylene at 1.4 μm

E Fasci, S Gravina, G Porzio, A Castrillo… - New Journal of …, 2021 - iopscience.iop.org
Doppler-free saturated-absorption Lamb dips are observed for weak vibration-rotation
transitions of C 2 H 2 between 7167 and 7217 cm− 1, using a frequency-comb assisted …

Comb-locked Lamb-dip spectrometer

D Gatti, R Gotti, A Gambetta, M Belmonte… - Scientific reports, 2016 - nature.com
Overcoming the Doppler broadening limit is a cornerstone of precision spectroscopy.
Nevertheless, the achievement of a Doppler-free regime is severely hampered by the need …

Sub-Doppler dispersion and noise-immune cavity-enhanced optical heterodyne molecular spectroscopy revised

O Axner, W Ma, A Foltynowicz - JOSA B, 2008 - opg.optica.org
An expression for the peak-to-peak sub-Doppler optical phase shift of two
counterpropagating modes of light, to which the noise-immune cavity-enhanced optical …

The Boltzmann constant from the H2 18O vibration–rotation spectrum: complementary tests and revised uncertainty budget

E Fasci, MD De Vizia, A Merlone, L Moretti… - Metrologia, 2015 - iopscience.iop.org
We report on complementary tests and measurements regarding our recent determination of
the Boltzmann constant, k B, by means of Doppler broadening thermometry, also providing …

NICE-OHMS—frequency modulation cavity-enhanced spectroscopy—principles and performance

O Axner, P Ehlers, A Foltynowicz, I Silander… - Cavity-Enhanced …, 2014 - Springer
Noise-immune cavity-enhanced optical heterodyne molecular spectroscopy (NICE-OHMS)
is a sensitive technique for detection of molecular species in gas phase. It is based on a …