Fuzzy logic-based diagnostic algorithm for implantable cardioverter defibrillators

A Bárdossy, A Blinowska, W Kuzmicz, J Ollitrault… - Artificial intelligence in …, 2014 - Elsevier
Objective The paper presents a diagnostic algorithm for classifying cardiac tachyarrhythmias
for implantable cardioverter defibrillators (ICDs). The main aim was to develop an algorithm …

Heart rate variability analysis to predict onset of ventricular tachyarrhythmias in implantable cardioverter defibrillators

A Parsi, D O'Loughlin, M Glavin… - 2019 41st Annual …, 2019 - ieeexplore.ieee.org
Implantable cardioverter defibrillators (ICDs) are commonly used in patients at high risk of
sudden cardiac death (SCD) to help prevent and treat life-threatening arrhythmia. Up to 80 …

Arrhythmia discrimination by physician and defibrillator: importance of atrial channel

I Diemberger, C Martignani, M Biffi, L Frabetti… - International journal of …, 2012 - Elsevier
BACKGROUND: Many ICD carriers experience inappropriate shocks, but the relative merits
of dual-/single-chamber devices for arrhythmia discrimination still remain unclear. We …

Inappropriate shocks in patients with ICDs: single chamber versus dual chamber

J Gonçalves, T Pereira - Arquivos brasileiros de cardiologia, 2013 - SciELO Brasil
Background: Despite the technological evolution of the implantable defibrillator, one of the
questions that remains is the possible benefit of the dual chamber versus single chamber …

[PDF][PDF] Prediction of ventricular tachyarrhythmias using fourier-bessel expansion in short-term HRV signals obtained from ICDs

AA Pouyan, A Parsi… - 11th Iranian Conference on …, 2013 - researchgate.net
Annually, many people die by cardiac murderous arrhythmias. Most of deathly arrhythmias
happen in ventricle. Ventricular tachycardia (VT) and ventricular fibrillation (VF) are the most …

A new approach for ICD rhythm classification based on support vector machines

B Kamousi, A Tewfik, B Lin, A Al-Ahmad… - … Conference of the …, 2009 - ieeexplore.ieee.org
Inappropriate shocks due to misclassification of supraventricular and ventricular arrhythmias
remain a major problem in the care of patients with implantable cardioverter defibrillators …

Classification of Atrio-Ventricular Reentrant Tachycardia using Intracardiac Signals

W Nafees, B Riaz, N Razzaq… - 13th IEEE International …, 2013 - ieeexplore.ieee.org
Electrophysiology study (EPS) has been serving as a diagnostic and curative tool for rhythm-
related cardiac diseases for more than few decades now. Clinical EPS requires intense …

[PDF][PDF] CARDIAC SIGNAL PROCESSING FOR CLASSIFICATION OF SUPRAVENTRICULAR TACHYCARDIA USING INTRACARDIAC SIGNALS

N RAZZAQ - 2017 - academia.edu
Electrophysiology study (EPS), a minimal invasive procedure, is performed in Cath lab for
investigation and therapeutic treatment of abnormality in cardiac rhythm using Intracardiac …

Choques inapropriados em portadores de CDI VR versus DR: meta-análise de ensaios clínicos randomizados

J Gonçalves, T Pereira - Arquivos Brasileiros de Cardiologia, 2013 - SciELO Brasil
FUNDAMENTO: Apesar da evolução tecnológica do cardiodesfibrilador implantável, uma
das questões que permanece em aberto é sobre o eventual benefício do cardiodesfibrilador …

[引用][C] 植入式除颤器腔内心电图的分析方法

沈俊乾, 郭萍, 孙卫新, 黄诒焯, 金捷 - 国际生物医学工程杂志, 2009