Gamma-and X-ray spectrometry with semiconductor detectors

K Debertin, RG Helmer - 1988 - inis.iaea.org
[en] This book covers the topics essential to γ-and X-ray spectrometry as it is now practiced
with semiconductor detectors in the energy range from 5KeV to 3 MeV. This includes useful …

Wide energy range efficiency calibration method for Ge detectors

GL Molnár, Z Révay, T Belgya - … and Methods in Physics Research Section …, 2002 - Elsevier
A new method is proposed for the relative efficiency calibration of HPGe detectors in the
energy range from 50keV to 11MeV. By simultaneously fitting all separately measured data …

Comparison of efficiency functions for Ge gamma-ray detectors in a wide energy range

Z Kis, B Fazekas, J Östör, Z Révay, T Belgya… - Nuclear Instruments and …, 1998 - Elsevier
The applicability of linear parameter functions for fitting the full-energy peak efficiency of Ge
gamma-ray detectors has been examined in a wide energy range of 50–8500keV, typical for …

The use of neutron intensity calibrated 9Be (α, n) sources as 4438 keV gamma-ray reference standards

S Croft - Nuclear Instruments and Methods in Physics Research …, 1989 - Elsevier
An accurate measurement of the 4438 keV γ-ray to total neutron ratio, R= S γ S n, for a
commercially obtained 3 mCi 241 Am 9 Be (α, n) source is described. The total neutron …

Beta Decay of the Ground State

EA Samworth, EK Warburton, GAP Engelbertink - Physical Review C, 1972 - APS
The decay scheme of the ground state of Al 26 has been reexamined by measurement of its
γ-ray spectrum with Ge (Li) detectors. The γ-ray spectrum shows very strong positron …

Absolute efficiency calibration of coaxial Ge (Li) detectors for the energy range 160–1330 keV

LA McNelles, JL Campbell - Nuclear Instruments and Methods, 1973 - Elsevier
A brief review of efficiency calibration techniques for Ge (Li) detectors is given, and the
necessity for precise interpolation between absolute efficiencies measured at specific …

Investigation of prompt γ-ray neutron activation spectrometer at the Dalat research reactor using Geant4 simulation

TT Chau, TT Tran, NS Pham, VT Chau - Radiation Physics and Chemistry, 2023 - Elsevier
The prompt γ-ray activation analysis (PGAA) detector, which has been developed at the
Dalat nuclear research reactor, is investigated in this study. The Geant4 model is proposed …

Precision measurements of gamma-ray intensities and energies in the decay of 152g, 154Eu, 56Co, 110mAg and 125Sb

G Aubin, J Barrette, M Barrette, S Monaro - Nuclear Instruments and …, 1969 - Elsevier
With the aid of a computarized program the relative intensities of the prominent transitions
present in the decay of 152g, 154 Eu, 56 Co, 110m Ag and 125 Sb have been calculated …

Relative efficiency of Ge (Li) gamma ray detectors from 0.5 to 12 MeV

BP Singh, HC Evans - Nuclear Instruments and Methods, 1971 - Elsevier
The double-escape peak efficiency for several Ge (Li) detectors has been measured
between 1.6 and 11.6 MeV using radioactive sources and gamma-ray cascades following …

[图书][B] Experimental neutron resonance spectroscopy

J Harvey - 2012 - books.google.com
Experimental Neutron Resonance Spectroscopy deals with the experimental technique of