Analysis by Monte Carlo methods of the response of an extended-range Bonner Sphere Spectrometer

R García-Baonza, GF García-Fernández… - Applied Radiation and …, 2020 - Elsevier
High-energy neutrons up to 230 MeV are generated as a consequence of (p, n) nuclear
reactions in proton therapy facilities. The aim of this work is to evaluate the potential …

A novel conceptualization in the analysis and design of passive neutron area monitors based on gold foil activation

R García-Baonza, GF García-Fernández… - Applied Radiation and …, 2022 - Elsevier
In the detection and measurement of neutron fields, with energies between 10 and 20 MeV,
current passive neutron area monitors based on gold foil sensors usually do not have a …

Monte Carlo characterization and benchmarking of extended range REM meters for its application in shielding and radiation area monitoring in Compact Proton …

GF García-Fernández, LE Cevallos-Robalino… - Applied Radiation and …, 2019 - Elsevier
Abstract Compact Proton Therapy Centers, CPTC, have a single treatment room, and are
technologically more affordable, smaller, advanced and easier to use. From a radiological …

Passive neutron area monitor with pairs of TLDs as neutron detector

HR Vega-Carrillo, KA Guzman-Garcia, E Gallego… - Radiation …, 2014 - Elsevier
A passive neutron area monitor has been designed using Monte Carlo methods; the monitor
is a polyethylene cylinder with pairs of thermoluminescent dosimeters (TLD600 and …

Comparison of extended-range and conventional Bonner Sphere Spectrometers (BSS) in an AmBe neutron field–Applicability of the ReBUNKI unfolding code for …

R García-Baonza, A Lorente, S Ibáñez… - Radiation Physics and …, 2023 - Elsevier
In proton therapy facilities, high-energy neutron fields are generated as a consequence of
(p, Xn) nuclear interactions. UPM has designed and tested its own extended-range Bonner …

Comparison of FANT results using the ENDF/B-VII. 1, JEFF-3.3 and TENDL2017 nuclear data libraries

LE Cevallos-Robalino, R García-Baonza… - Applied Radiation and …, 2022 - Elsevier
Abstract FANT (Fuente Ampliada de Neutrones Térmicos; in Spanish) is a thermal neutron
irradiation facility with an extended and very uniform irradiation area, that has been …

A new response matrix for a 6LiI scintillator BSS system

MAS Lacerda, R Méndez-Villafañe, A Lorente… - Nuclear Instruments and …, 2017 - Elsevier
A new response matrix was calculated for a Bonner Sphere Spectrometer (BSS) with a 6 LiI
(Eu) scintillator, using the Monte Carlo N-Particle radiation transport code MCNPX …

Analysis by Monte Carlo of thermal neutron flux from a 241Am/9Be source for a system of trace analysis in materials

LE Cevallos-Robalino, GF García-Fernández… - Applied Radiation and …, 2019 - Elsevier
Neutron techniques to characterize materials have a wide range of applications, one of the
major developments being the identification of terrorist threats with chemical, biological …

Application of an algebraic methodology for the combination of Berthold LB6411 and WENDI-II for neutron area monitoring in DT neutron generators and fusion …

R García-Baonza, E Gallego… - Applied Radiation and …, 2022 - Elsevier
Neutron area monitors do not often have a good adjustment of their dose response functions
to the ICRP74 neutron fluence-to-H*(10) conversion function between 10 and 20 MeV. The …

Estimation with Monte Carlo of thermal neutrons in the FANT, using 252Cf and 241Am/9Be neutron source

LE Cevallos-Robalino, G García-Fernández… - Applied Radiation and …, 2023 - Elsevier
The thermal neutron irradiation device (FANT), developed at the Neutron Measurements
Laboratory of the Energy Engineering Department at Universidad Politécnica de Madrid, is a …