Partial discharge diagnosis and remaining useful lifetime in XLPE extruded power cables under DC voltage: a review

M Fikri, Z Abdul-Malek - Electrical Engineering, 2023 - Springer
This paper collects, summarizes, and discusses more than a hundred important works on
various causes, approaches, and advances in the supervision and diagnosis of extruded …

Numerical Modeling of PD Pulses Formation in a Gaseous Void Located in XLPE Insulation of a Loaded HVDC Cable

P Mikrut, P Zydroń - Energies, 2023 - mdpi.com
Power cables are one of the key components of fast-growing HVDC transmission systems.
The long-term reliability of HVDC cables is closely related to the occurrence of partial …

Life Estimation of HVDC Cables Subjected to Fast and Slow Polarity Reversals

B Diban, G Mazzanti, M Marzinotto, A Battaglia - Energies, 2024 - mdpi.com
This paper aims at estimating the life of extruded HVDC cable insulation subjected to fast
and slow voltage polarity reversals (VPRs). An ad hoc MATLAB code is used for the …

Space Charge and Electric Field Dependent on Polarity Reversal of HVDC Cable Insulation

Z Li, Z Zheng, Y Wu, B Du - IEEE Transactions on Dielectrics …, 2023 - ieeexplore.ieee.org
This article focuses on the effect of the polarity reversal on the space charge behavior and
electric field evolution of±500-kV HVDC cables under different temperature gradients. A …

Electric Field Distribution after Polarity Reversal in HVDC Cables: The Effect of Insulation Characteristics

B Diban, G Mazzanti, M Marzinotto… - 2022 IEEE Conference …, 2022 - ieeexplore.ieee.org
This paper investigates the effect of the electrical and the thermal characteristics of the
insulating material of HVDC cables on the transient development during and after fast and …

Research of the Inverse Relationship between Internal and External Temperatures of 10 kV Three-core Cable Joints

L Chen, R Niu, H Zhou - IEEE Access, 2024 - ieeexplore.ieee.org
Cable joint temperature monitoring can effectively warn of overloading problems, but the
existing sensors are often attached to the surface of the cable joints, which can detect only …

The Effect of Superimposed Switching Impulses on Space Charge Accumulation in XLPE-insulated HVDC Cables

B Diban, G Mazzanti, P Seri - 2023 IEEE Conference on …, 2023 - ieeexplore.ieee.org
Electrical apparatus including HVDC cables are subject to transient events during their
operating lifetime. This paper studies the effect of Superimposed Switching Impulses (SSIs) …

Synergistic Effect of Polarity Reversals and Load Current on Life of HVDC Cable Insulation

DP Borthakur, AR Verma - 2023 4th International Conference …, 2023 - ieeexplore.ieee.org
The paper presents a mathematical model for estimating the degradation/aging of a HVDC
cable considering the combined effect of polarity reversal of applied voltage and load …

Models for reliability estimation of HVDC cable systems

B Diban - 2023 - amsdottorato.unibo.it
The work carried out in this thesis aims at:-studying–in both simulative and experimental
methods–the effect of electrical transients (ie, Voltage Polarity Reversals VPRs, Temporary …

Simulation of Thermal and Electrical Transient Field Distribution of a HVDC Cable Laid in a Tunnel

X Wang, B Huang, W Cai, J Wen, X Liu… - 2024 IEEE 7th …, 2024 - ieeexplore.ieee.org
The rapid development of high voltage direct current (HVDC) transmission technology has
put forward increasingly higher requirements for the key technologies of HVDC cables …