Cyber-enabled grids: Shaping future energy systems

PWT Pong, AM Annaswamy, B Kroposki… - Advances in Applied …, 2021 - Elsevier
As the penetration of distributed energy resources based on renewable sources increases,
several technical challenges are introduced into energy grids. These include real-time …

The study on a new method for measurement of electric fast transient voltage based on electric induction of metal slice

B Lu, S Gao, L Song, J Xiong - IEEE Transactions on Industrial …, 2020 - ieeexplore.ieee.org
Accurate measurement of electric fast transient (EFT) voltage is very important for insulation
design and fault analysis of electric apparatus. In this article, a new simple method for EFT …

Non-intrusive voltage-inversion measurement method for overhead transmission lines based on near-end electric-field integration

W Liao, Q Yang, K Ke, Z Qiu, Y Lei, F Jiao - Energies, 2023 - mdpi.com
Existing electric-field integral inversion methods have limited field application conditions,
and they are difficult to arrange electric-field measurement points on high-span overhead …

The study on a new method for measurement of the surge voltage of 10/700 μs based on electric induction of the metal slice

B Lu, L Song, J Xiong, S Gao - IEEE Transactions on …, 2021 - ieeexplore.ieee.org
The accurate measurement of the transient fault voltage is helpful to the control, protection,
condition monitoring, and evaluation of the power system. In this article, a simple and …

A New Method for Voltage Measurement with Harmonic Voltage Amplification in the 10 kV Cable

H Pang, B Lu, X Sun - IEEE Transactions on Instrumentation …, 2023 - ieeexplore.ieee.org
The penetration rate of power electronic equipment and renewable resources in power
system has rapidly grown recently, which may bring harmonic pollution. Therefore, the …

Harmonic Voltage Measurement Based on Capacitive Equipment Dielectric Equivalent Model and Responding Current

L Du, H Feng, X Li, X Shao, Z Yang - Measurement Science and …, 2024 - iopscience.iop.org
With the increasing proportion of new energy and the power electronic equipment in the
power grid, accurate measurement of harmonic voltage has become increasingly important …

Simplified decoupling simulation study of non‐contact voltage measurement in distribution station area

L Liu, T Wang, J Shen, R Li, F Li… - IET Generation …, 2024 - Wiley Online Library
The coupling capacitance between the line and the transducer cannot be ignored when
making non‐contact voltage measurements on low‐voltage three‐phase power lines. This …

Non-contact voltage measurement technology based on dual coupling mechanism displacement current method

Y Peng, L Fu, Y Ye, H Li - 2023 IEEE 4th China International …, 2023 - ieeexplore.ieee.org
The distribution network is located in a complex environment, and the installation height of
the line and the time-varying parameters of the surrounding medium all cause changes in …

Non-contact voltage measurement device and diagnosis system

T Kato, M Nagata, K Maki - US Patent 11,047,882, 2021 - Google Patents
Provided are a non-contact voltage measurement device and diagnosis system capable of
acquiring the voltage of an electric wire without disconnecting the wire. The non-contact …

Research on Measurement Principle and Electrode Optimization of Non-Intrusive MEMS Voltage Sensor Based on Charge Induction

Y Lei, F Jiao, Q Yang, W Liao, K Ke… - 2023 Panda Forum on …, 2023 - ieeexplore.ieee.org
On the basis of the existing non-intrusive Micro-Electro-Mechanical System (MEMS) voltage
sensor based on charge induction, the sensing mechanism of the sensor is studied and the …