Structural fire performance of wood-steel-wood bolted connections with and without perpendicular-to-wood grain reinforcement

AR Petrycki, O Salem - Journal of Structural Fire Engineering, 2023 - emerald.com
Purpose In fire condition, the time to failure of a timber connection is mainly reliant on the
wood charring rate, the strength of the residual wood section, and the limiting temperature of …

Fire resistance of a fully concealed, moment-resisting new timber connection utilizing mechanically-fastened steel rods

C Hubbard, O Salem - Fire Safety Journal, 2022 - Elsevier
One major hindrance to more utilization of timber in the construction of tall buildings is the
limited fire resistance of the connections between its structural elements. In an experimental …

Fire Tests on Steel–Timber Composite Beams

A Béreyziat, D Dhima, S Durif, M Audebert, A Bouchaïr… - Fire Technology, 2024 - Springer
The fire resistance and the thermomechanical behaviour of Steel–Timber Composite (STC)
beams are studied through 4 fire tests. 35 non-loaded reduced specimens and 2 …

Modelling of fire performance of Cross Laminated Timber (CLT) panels

TT Tran, M Khelifa, A Nadjai, M Oudjene… - Journal of Physics …, 2018 - iopscience.iop.org
A numerical method has been developed to incorporate the effects of heat transfer in a CLT
panel exposed to fire. The procedure has been added into the software package Abaqus [1] …

Fires in Narrow Construction Cavities: Fire Dynamics and Material Fire Performance

K Livkiss - 2020 - portal.research.lu.se
There have recently been devastating fire incidents related to fire spread over ventilated
façades. These incidents indicate gaps in our understanding of the fire behaviour of façades …

Fire resistance performance of glulam beam

C Chen, J Yang, J Chen, J Zeng, W Wang… - Journal of Central South …, 2017 - Springer
A glulam beam with the size of 4700 mm× 300 mm× 480 mm (L× W× H) was tested in the
furnace to investigate the fire resistance performance of glulam beam according to the …

Fire performance of a novel concealed mass timber moment-resisting connection utilizing mechanically-fastened steel rods

C Hubbard - 2020 - knowledgecommons.lakeheadu.ca
A major hindrance to more application of engineered-wood products in the Canadian
building construction market is the lack of technical documentations and guidelines for the …

Wood as Fire Protection of Steel in Hybrid Structural Elements

V Saulnier, S Durif, S Oulboukhitine, A Bouchaïr… - Wood & Fire Safety …, 2020 - Springer
Various solutions are used for steel-timber hybrid elements that associate two timber beams
on both sides of a steel plate or a steel profile. Steel is used as mechanical reinforcement to …

Wood as Fire Protection of Steel in Hybrid Structural Elements

A Bouchaïr, G Bihina - Wood & Fire Safety: Proceedings of the …, 2020 - books.google.com
Various solutions are used for steel-timber hybrid elements that associate two timber beams
on both sides of a steel plate or a steel profile. Steel is used as mechanical reinforcement to …

[PDF][PDF] POUŽITÍ POČÍTAČOVÉHO MODELOVÁNÍ PŘI ŘEŠENÍ VYBRANÝCH ÚLOH MATERIÁLOVÉHO INŽENÝRSTVÍ

J Maděra - portal.fsv.cvut.cz
Anotace Hlavním tématem této habilitační práce je počítačové modelování v materiálovém
inženýrství. V první kapitole je uvedena rešerše použití počítačového modelování ve světě a …