[HTML][HTML] A method to obtain radioactivity of non-γ nuclides by 60Co based on Monte Carlo simulations

Y Shi, Y Xiang, R Su, B Hu, S Sun, Z Liu - Nuclear Engineering and …, 2024 - Elsevier
Source term investigation is a critically important aspect of reactor decommissioning,
particularly as the range of nuclides under consideration expands beyond the capabilities of …

Numerical modelling of environmental dose rate and its application to trapped-charge dating

R Nathan - 2010 - ora.ox.ac.uk
Accurate estimation of environmental dose rate is essential for high-resolution trapped-
charge dating. Beta and gamma emissions from simulated sediments containing radioactive …

Evaluation of Lung Dose in Esophageal Cancer Radiotherapy Using Monte Carlo Simulation

T Pourfallah, M Seyed Abousaeedi… - … of Medical Sciences, 2020 - jmums.mazums.ac.ir
Background and purpose: Radiation therapy make an important contribution in the control
and treatment of cancers. Lungs are the main organs at risk in esophageal cancer …

[HTML][HTML] CALCULATION OF SPINAL CORD RECEIVED DOSE IN ESOPHAGEAL CANCER RADIOTHERAPY: A COMPARISON BETWEEN MONTE CARLO …

T Pourfallah, M Nematpour… - Studies in Medical …, 2024 - umj.umsu.ac.ir
Background & Aim: Spinal cord is one of the organs at risk in esophageal cancer radiation
therapy. The difference between the dose distribution due to the Treatment Planning System …

Identificação e quantificação de fotossensibilizador em tecido hepático por espectroscopia de fluorescência e sua importância na terapia fotodinâmica

JD Vollet Filho - 2007 - teses.usp.br
A Terapia Fotodinâmica (TFD) é uma técnica que provoca dano celular pela ação de um
fotossensibilizador (FS), com seletividade de localização em tecido tumoral; a luz que …

[PDF][PDF] محاسبه دز دریافتی نخاع در پرتودرمانی سرطان مری؛ مقایسه شبیه‌سازی مونت‌کارلو و سیستم طراحی درمان

پورفلاح, طیب, نعمت پور, محمد, سیفی ماکرانی… - مجله مطالعات علوم …, 2024‎ - umj.umsu.ac.ir
Pourfallah T, Nematpour M, Seifi Makrani D, Mihandoust E, Davodian S. CALCULATION OF
SPINAL CORD RECEIVED DOSE IN CANCER RADIOTHERAPY: A COMPARISON …

CT-based brachytherapy treatment planning using Monte Carlo simulation aided by an interface software

V Moslemi, A Esmaili-Torshabi… - Iranian Journal of …, 2011 - ijmp.mums.ac.ir
Introduction: In brachytherapy, radioactive sources are placed close to the tumor, therefore,
small changes in their positions can cause large changes in the dose distribution. This …

[PDF][PDF] Modificação de polietileno por copolimerização de enxerto induzida por radiação gama: sua aplicação na área dos biomateriais

LM Ferreira - 2008 - repositorio.ul.pt
A avaliação dos resultados obtidos, a partir da análise de regressão linear dos dados
dosimétricos, mostra que as rectas mais prováveis não interceptam a origem dos eixos …

Simulation of the dose rate using a GEANT 4 code

E Jemii, L Ghedira - 2014 International Conference on …, 2014 - ieeexplore.ieee.org
Many authors have used a Monte Carlo simulation to determine the dose rate deposited in a
given target, such as the GEANT 4 code [1, 2, 3] or the MCNP code [4, 5, 6]. In the present …

بررسی دز ریه در پرتودرمانی سرطان مري به روش شبیه سازي مونت کارلو

طیب پورفلاح, محمد سیدابوسعیدي… - … of Medical Sciences …, 2020‎ - search.ebscohost.com
Background and purpose: Radiation therapy make an important contribution in the control
and treatment of cancers. Lungs are the main organs at risk in esophageal cancer …