HIFU drive system miniaturization using harmonic reduced pulsewidth modulation

C Adams, TM Carpenter, D Cowell… - IEEE transactions on …, 2018 - ieeexplore.ieee.org
Switched excitation has the potential to improve on the cost, efficiency, and size of the linear
amplifier circuitry currently used in high-intensity focused ultrasound (HIFU) systems …

High-power gallium nitride HIFU transmitter with integrated real-time current and voltage measurement

TM Carpenter, DMJ Cowell, HR Clegg… - … Circuits and Systems, 2021 - ieeexplore.ieee.org
High-Intensity Focused Ultrasound (HIFU) therapy provides a non-invasive technique with
which to destroy cancerous tissue without using ionizing radiation. To drive large single …

[HTML][HTML] Optimizing the lateral beamforming step for filtered-delay multiply and sum beamforming to improve active contour segmentation using ultrafast ultrasound …

AM Moubark, Z Alomari, MHM Zaman… - … Signal Processing and …, 2022 - Elsevier
As an alternative to delay-and-sum beamforming, a novel beamforming technique called
filtered-delay multiply and sum (FDMAS) was introduced recently to improve ultrasound B …

Using Heterogeneous Hardware for Simultaneous Diagnostic and Therapeutic Ultrasound

HR Clegg, TM Carpenter… - 2019 IEEE …, 2019 - ieeexplore.ieee.org
Within the Ultrasound Array Research Platform (UARP) open research system project,
imaging and high-intensity focussed ultrasound (HIFU) implementations are used …

HIFU power monitoring using combined instantaneous current and voltage measurement

C Adams, JR McLaughlan… - IEEE transactions on …, 2019 - ieeexplore.ieee.org
During high-intensity focused ultrasound (HIFU) therapy, it is important that the electrical
power delivered to the transducer is monitored to avoid underexposure or overexposure …

Modified harmonic reduction pulse width modulation (mhrpwm) for switched excitation of resonant hifu transducers

DMJ Cowell, TM Carpenter, C Adams… - 2018 IEEE …, 2018 - ieeexplore.ieee.org
High Intensity Focused Ultrasound (HIFU) is reliant on carefully designed excitation systems
capable of high power, and low distortion. The use of array transducers additionally requires …

A miniature HIFU excitation scheme to eliminate switching-induced grating lobes and nullify hard tissue attenuation

C Adams, DMJ Cowell, L Nie… - 2017 IEEE …, 2017 - ieeexplore.ieee.org
Phased array transducers are increasingly prevalent in a therapeutic contex as they facilitate
precise control of the beam intensity and focus. To produce enough acoustic energy for …

Large-scale trials of a real-time acoustic backscatter system for solids concentration measurement during nuclear waste cleanup

DMJ Cowell, T Carpenter, S Freear… - 2016 IEEE …, 2016 - ieeexplore.ieee.org
Real time in situ characterisation of solids concentration would aid operational
understanding and improve efficiency in many industrial systems. This is especially true in …

Phase Dithered Modulation in Switched Mode Excitation for Improved Amplitude Control

DMJ Cowell, TM Carpenter, HR Clegg… - 2019 IEEE …, 2019 - ieeexplore.ieee.org
Multi-level switched mode transmitters provide a simplified method of exciting ultrasound
transducers compared to linear amplifiers. Excitation waveforms are created which switch …

A Testbench System for Structural Health Monitoring with Guided-Wave Ultrasound

P Giannelli - 2018 - flore.unifi.it
This dissertation covers the design of the transducers and electronics of a structural health
monitoring (SHM) testbench system targeted at plate-like structures. The health inspection …