A review on preparation methods and measurement techniques of reference gas mixtures

D Soni - Microchemical Journal, 2024 - Elsevier
Use of reference materials (RMs) in analytical laboratories has been increased from past
several years. The purpose is traceability and accuracy in measurement results. The RMs …

Development of an International System of Units (SI)-traceable transmission curve reference material to improve the quantitation and comparability of proton-transfer …

DR Worton, S Moreno, K O'Daly… - Atmospheric …, 2023 - amt.copernicus.org
Since its inception more than 2 decades ago, proton-transfer-reaction mass spectrometry
(PTR-MS) has established itself as a powerful technique for the measurements of a wide …

Extrapolation schemes of key comparison results in gas analysis

AMH van der Veen, H Meuzelaar - Metrologia, 2021 - iopscience.iop.org
Abstract The GAWG (Gas Analysis Working Group of the Consultative Committee for Amount
of Substance: Metrology in Chemistry and Biology) has developed an extrapolation scheme …

On the traceability of gaseous reference materials

RJC Brown, PJ Brewer, PM Harris, S Davidson… - Metrologia, 2017 - iopscience.iop.org
The complex and multi-parameter nature of chemical composition measurement means that
establishing traceability is a challenging task. As a result incorrect interpretations about the …

International comparison CCQM-K111. 1—propane in nitrogen

AMH van der Veen, JW van der Hout, PR Ziel… - Metrologia, 2017 - iopscience.iop.org
This key comparison aims to assess the core capabilities of the participants in gas analysis.
Such competences include, among others, the capability of preparing Primary Standard gas …

Benchmarking the success of CCQM key comparisons for metrology institutes and their stakeholders

PJ Brewer, RJC Brown - Metrologia, 2020 - iopscience.iop.org
Key comparisons provide the means to assess the comparability of measurement
capabilities at National Metrology Institutes and Designated Institutes worldwide. In addition …

[PDF][PDF] 4 Supported CMC claims

V ER, M ETR - International Comparison CCQM-K3. 2019 Automotive … - researchgate.net
4 Supported CMC claims Page 14 CCQM-K3. 2019 Final Report 14 VSL C ER I IN M ETR O IPQ
KR ISS N IST NM ISA N PL VN IIM -0.0008 -0.0006 -0.0004 -0.0002 0.0000 0.0002 0.0004 …

International comparison Euramet. QM-K111—propane in nitrogen

JW van der Hout, AMH van der Veen, PR Ziel… - Metrologia, 2017 - iopscience.iop.org
International comparison Euramet.QM-K111—propane in nitrogen - IOPscience This site uses
cookies. By continuing to use this site you agree to our use of cookies. To find out more, see …

[PDF][PDF] International Comparison CCQM-K41. 2017

D Kim, YD Kim, S Lee, D Smeulders, H Wu, J Fuko… - researchgate.net
Hydrogen sulfide is a naturally occurring compound encountered in petroleum, natural gas
and other drilling operations, mining, and sewers. Hydrogen sulfide is a poisonous gas …

[PDF][PDF] International Comparison APMP. QM-K111–Propane in nitrogen

S Uehara, T Nishino, TYL Dai Akima, HW Liu… - researchgate.net
This APMP key comparison is one of a series of key comparisons in the gas analysis area
assessing core competences (track A key comparisons). Such competences include, among …