Pollution flashover voltage of transmission line insulators: Systematic review of experimental works

AA Salem, KY Lau, W Rahiman, Z Abdul-Malek… - IEEE …, 2022 - ieeexplore.ieee.org
Over the past decades, extensive experimental-based research works have been carried out
to investigate the flashover phenomenon on the performance of polluted transmission line …

Leakage current characteristics in estimating insulator reliability: experimental investigation and analysis

AA Salem, KY Lau, W Rahiman, Z Abdul-Malek… - Scientific Reports, 2022 - nature.com
The monitoring of leakage current (LC) and voltage characteristics in transmission line
insulators is regarded as a good technique for anticipating the physical state of in-service …

Experimental study of pollution and simulation on insulators using COMSOL® under AC voltage

H Benguesmia, B Bakri, S Khadar, F Hamrit… - Diagnostyka, 2019 - yadda.icm.edu.pl
The flashover of pollution, observed on the insulators used in high voltage transmission, is
one of the most important power transmission stakes. It is a very complex problem due to …

FEM analysis of polluted 230 kV porcelain insulators by introducing new asymmetrical contamination: Elliptical ring-shaped

H Fadaeeasrami, F Faghihi, J Olamaei… - International Journal of …, 2022 - Elsevier
High voltage (HV) insulator of power transmission lines is affected by environmental
conditions that can be led to insulator aging through leakage current enhancement and …

Performance evaluation of outdoor high voltage glass insulators in high pollution industrial areas using simulated acid rain contamination

C Ilomuanya, S Farokhi, A Nekahi - IEEE Access, 2022 - ieeexplore.ieee.org
A suitable, non-standard method for artificial pollution testing using simulated acid rain
pollution in a laboratory was developed in this work. The method is applicable to a wide …

Comparative analysis of electric field and potential distributions over porcelain and glass insulators using finite element method

AS Krzma, MY Khamaira, M Abdulsamad - 2018 - dspace.elmergib.edu.ly
This paper investigates the electrical performance of outdoor porcelain and glass insulators
when subjected to an 11 kV AC voltage. The insulators are modeled in two dimensions, and …

Comparative characterisation of conventional and textured 11 kV insulators using the rotating wheel dip test

A Krzma, M Albano, A Haddad - High Voltage, 2020 - Wiley Online Library
Surface tracking and erosion is an irreversible degradation occurring on the insulator
surface, and this can ultimately lead to failure of the insulator. Polymeric materials such as …

Analyzing the Root Cause for Insulator Failure through Investigating the Insulator Performance under Environmental Stresses

M Batalovic, M Matoruga, H Zildzo… - 2024 5th International …, 2024 - ieeexplore.ieee.org
Previous investigations result with issues regarding insulators premature aging and
degradation process. Recent case of an outage in power plant showed unusual pattern of …

[PDF][PDF] Computation of the electric field and voltage distributions over the polluted surface of silicone-rubber insulators

AS Krzma, MY Khamaira - Elixir Elec. Engg, 2018 - researchgate.net
This paper investigates the performance of an 11 kV silicone rubber (SiR) outdoor insulator
when subjected to an alternative voltage at 50 Hz. The electrical field and potential …

The High Voltage Performance of Inclined Insulators

C Plaengpraphan - 2023 - search.proquest.com
The use of insulators at non-standard angles in high voltage overhead power lines and in
the railway system has widely increased. The main purposes of this are to reduce the …