Determination of rare earth elements in natural water samples–A review of sample separation, preconcentration and direct methodologies

A Fisher, D Kara - Analytica chimica acta, 2016 - Elsevier
This review discusses and compares the methods given for the determination of rare earth
elements (REE) in natural water samples, including sea, river, lake, tap, ground and waste …

Overview of analytical methodologies for sea water analysis: Part I—Metals

TP Rao, P Metilda, JM Gladis - Critical Reviews in Analytical …, 2005 - Taylor & Francis
A comprehensive, critical and up-to-date review of analytical methods developed during the
last decade for metals present in sea water is presented. Separate sections are devoted to …

The fabrication of potentiometric membrane sensors and their applications

F Faridbod, MR Ganjali, R Dinarvand… - African Journal of …, 2007 - ajol.info
Ionophore-incorporated PVC-membrane sensors are well-established analytical tools
routinely used for the selective and direct measurement of a wide variety of different ions in …

Lanthanide recognition: An asymetric erbium microsensor based on a hydrazone derivative

F Faridbod, MR Ganjali, B Larijani, P Norouzi, S Riahi… - Sensors, 2007 - mdpi.com
N'-(2-hydroxy-1, 2-diphenylethylidene) benzohydrazide (HDB) was found to have a very
selective and sensitive behavior towards erbium (III) ions, in comparison to thirteen …

A novel Er (III) sensor based on a new hydrazone for the monitoring of Er (III) ions

MR Ganjali, F Faridbod, P Norouzi, M Adib - Sensors and Actuators B …, 2006 - Elsevier
N′-(2-Hydroxy-1, 2-diphenylethylidene) benzohydrazide (HDEBH) was found to be a
suitable neutral pseudo-ionophore for the preparation of a highly selective Er (III) membrane …

Determination of erbium ions in water samples by a pvc membrane erbium-ion selective electrode

HA Zamani, M Mohammadhosseini, M Nekoei… - Sensor …, 2010 - ingentaconnect.com
A highly sensitive erbium (III) polymeric membrane sensor based on ethylene glycol (2-
aminoethyl)-N, N, N′, N′-tetraacetic acid (EGTA) as sensing material, poly (vinyl …

Novel erbium (III)-selective fluorimetric bulk optode

MR Ganjali, M Hosseini, M Hariri, F Faridbod… - Sensors and Actuators B …, 2009 - Elsevier
For the first time a highly sensitive and selective fluorimetric optode membrane was
prepared for the determination of trace amounts of Er (III) ions. The Er (III) sensing system …

[HTML][HTML] Fabrication of a new samarium (III) ion-selective electrode based on 3-{[2-oxo-1 (2H)-acenaphthylenyliden] amino}-2-thioxo-1, 3-thiazolidin-4-one

HA Zamani, MR Ganjali, M Adib - Journal of the Brazilian Chemical …, 2007 - SciELO Brasil
This paper introduces the development of an original PVC membrane electrode, based on 3-
{[2-oxo-1 (2H)-acenaphthylenyliden] amino}-2-thioxo-1, 3-thiazolidin-4-one (ATTO) which …

Application of Pyridine-2-carbaldehyde-2-(4-methyl-1, 3-benzo thiazol-2-yl) hydrazone as a Neutral Ionophore in the Construction of a Novel Er (III) Sensor

MR Ganjali, M Rezapour, S Rasoolipour… - Journal of the Brazilian …, 2007 - SciELO Brasil
We found that pyridine-2-carbaldehyde-2-(4-methyl-1, 3-benzothiazol-2-yl) hydrazone
(PCMHT) can be used as a suitable neutral ionophore for preparing an Er (III) membrane …

Palladium-catalysed reactions of 8-hydroxy-and 8-benzyloxy-5, 7-diiodoquinoline under aminocarbonylation conditions

A Takács, A Szilágyi, P Ács, L Márk, AF Peixoto… - Tetrahedron, 2011 - Elsevier
Various 5-carboxamido-7-iodo-8-benzyloxyquinolines were synthesised via selective
aminocarbonylation of 5, 7-diiodo-8-benzyloxyquinoline in the presence of 'in situ'generated …