Verification and validation of large eddy simulation with Nek5000 for cold leg mixing benchmark
Large eddy simulation (LES) of an experimental benchmark investigating buoyant mixing
among two fluids is developed for verification and validation. Flow physics involve a …
among two fluids is developed for verification and validation. Flow physics involve a …
Results of thermal mixing tests at the HDR-facility and comparisons with best-estimate and simple codes
L Wolf, U Schygulla, W Haeffner, K Fischer… - … Engineering and Design, 1987 - Elsevier
This paper reports about experimental and analytical results of a first series of three thermal
mixing experiments at HDR with high-pressure cold water injection (20° C) into one cold leg …
mixing experiments at HDR with high-pressure cold water injection (20° C) into one cold leg …
PTS thermal hydraulic testing in the OSU APEX facility
JN Reyes, JT Groome, AY Lafi, D Wachs… - International journal of …, 2001 - Elsevier
The APEX Test Facility at Oregon State University has been modified to simulate a typical 2×
4 loop Combustion Engineering nuclear plant. The new configuration, APEX-CE, will be …
4 loop Combustion Engineering nuclear plant. The new configuration, APEX-CE, will be …
A unified interpretation of one-fifth to full scale thermal mixing experiments related to pressurized thermal shock
TG Theofanous, H Yan - 1991 - osti.gov
Thermal mixing in relation to Pressurized Thermal Shock has been examined
experimentally throughout the world in a variety of scales. These include the CREARE-1/5 …
experimentally throughout the world in a variety of scales. These include the CREARE-1/5 …
An analytical mixing model for buoyant jet injected into pipe flow
JH Kim - 1985 - asmedigitalcollection.asme.org
An analytical model based on jet trajectory, jet diffusion layer, and flow establishment which
predicts mixing of a cold jet injected at an angle into a hot crossflow in a horizontal pipe is …
predicts mixing of a cold jet injected at an angle into a hot crossflow in a horizontal pipe is …
A criterion for predicting thermal stratification due to high-pressure injection in a circulating reactor loop
HP Nourbakhsh, TG Theofanous - Nuclear Science and …, 1986 - Taylor & Francis
A Criterion for Predicting Thermal Stratification Due to High-Pressure Injection in a Circulating
Reactor Loop Page 1 NUCLEAR SCIENCE AND ENGINEERING: 94, 77-79 (1986) Technical …
Reactor Loop Page 1 NUCLEAR SCIENCE AND ENGINEERING: 94, 77-79 (1986) Technical …
Investigation of fluid mixing with direct vessel injection
JH Cha, HG Jun - Nuclear engineering and design, 1994 - Elsevier
The object of this work is to investigate fluid mixing phenomena as they related to
pressurized thermal shock (PTS) in a pressurized water reactor vessel downcomer during …
pressurized thermal shock (PTS) in a pressurized water reactor vessel downcomer during …
Mixing phenomena of interest to SBLOCAs
TG Theofanous, K Iyer - Nuclear Engineering and Design, 1987 - Elsevier
Small break LOCAs may lead to flow stagnation with high primary system pressure. The
thermal mixing of the high pressure safety injection under such conditions has important …
thermal mixing of the high pressure safety injection under such conditions has important …
[PDF][PDF] uS Transactions of the 15" International Conference on 篮》 Structural Mechanics in Reactor Technology (SMiRT-15) Z. Scoul, Korea, August 15-20, 1999 [307/3
KM Hwang, HK Youm, YH Seo, TE Jin - repository.lib.ncsu.edu
The thermal stratification phenomenon of Reactor Coolant System (RCS) piping and the
formation of cold water plume of Reactor Pressure Vessel (RPV) downcomer, when High …
formation of cold water plume of Reactor Pressure Vessel (RPV) downcomer, when High …
Derivation of mixing parameters from the HDR-thermal mixing experiments
W Häfner, L Wolf - International Journal of Pressure Vessels and Piping, 1988 - Elsevier
This paper presents the results of an analysis and interpretation of mixing phenomena in the
cold leg near the injection nozzle during the high-pressure injection (HPI) of cold emergency …
cold leg near the injection nozzle during the high-pressure injection (HPI) of cold emergency …