ANTS2 package: simulation and experimental data processing for Anger camera type detectors

A Morozov, V Solovov, R Martins, F Neves… - Journal of …, 2016 - iopscience.iop.org
ANTS2 is a simulation and data processing package developed for position sensitive
detectors with Anger camera type readout. The simulation module of ANTS2 is based on …

Characterization of new FBK SiPM technology for visible light detection

N Serra, A Ferri, A Gola, T Pro, A Tarolli… - Journal of …, 2013 - iopscience.iop.org
This paper presents the characterization of the new n-on-p SiPM technology developed at
Fondazione Bruno Kessler (FBK, Trento-Italy). Several device aspects such as dark count …

A large area, silicon photomultiplier-based PET detector module

RR Raylman, A Stolin, S Majewski, J Proffitt - Nuclear Instruments and …, 2014 - Elsevier
The introduction of silicon photomultipliers (SiPM) has facilitated construction of compact,
efficient and magnetic field-hardened positron emission tomography (PET) scanners. To …

Evaluation of imaging modules based on SensL array SB-8 for nuclear medicine applications

AV Stolin, S Majewski, G Jaliparthi… - 2013 IEEE Nuclear …, 2013 - ieeexplore.ieee.org
Recent advances in the development of silicon photomultipliers (SiPM) offer new
opportunities for medical imaging applications. Specifically, novel imaging devices for …

[图书][B] Radiation detectors for medical imaging

JS Iwanczyk - 2015 - books.google.com
Radiation Detectors for Medical Imaging discusses the current state of the art and future
prospects of photon-counting detectors for medical imaging applications. Featuring …

A multichannel and compact time to digital converter for time of flight positron emission tomography

N Marino, F Baronti, L Fanucci… - … on Nuclear Science, 2015 - ieeexplore.ieee.org
This paper presents a novel multichannel time to digital converter (TDC) specifically
designed for the digitization of photon time of flight (TOF) and energy in positron emission …

Development of an ultrahigh resolution block detector based on 0.4 mm pixel Ce: GAGG scintillators and a silicon photomultiplier array

S Yamamoto, JY Yeom, K Kamada… - … on Nuclear Science, 2013 - ieeexplore.ieee.org
Ce doped Gd 3 Al 2 Ga 3 O 12 (Ce: GAGG) is a newly developed single-crystal scintillator
which has a large light output and longer emission light wavelength. The longer wavelength …

Depth of interaction determination in monolithic scintillator with double side SiPM readout

M Morrocchi, G Ambrosi, MG Bisogni, F Bosi, M Boretto… - EJNMMI physics, 2017 - Springer
Background Monolithic scintillators read out by arrays of photodetectors represent a
promising solution to obtain high spatial resolution and the depth of interaction (DOI) of the …

A Monte Carlo investigation of the spatial resolution performance of a small-animal PET scanner designed for mouse brain imaging studies

M Rodríguez-Villafuerte, Y Yang, SR Cherry - Physica Medica, 2014 - Elsevier
Our laboratory has developed PET detectors with depth-encoding accuracy of∼ 2 mm
based on finely pixelated crystals with a tapered geometry, readout at both ends with …

Immersion cooling of silicon photomultipliers (SiPM) for nuclear medicine imaging applications

RR Raylman, AV Stolin - Radiation Measurements, 2016 - Elsevier
Silicon photomultipliers (SiPM) are compact, high amplification light detection devices that